MM0009/0304 issue 1.
LIABILITY DISCLAIMER NEC Corporation reserves the right to change the specifications, functions, or features, at any time, without notice. NEC Corporation has prepared this document for use by its employees and customers. The information contained herein is the property of NEC Corporation and shall not be reproduced without prior written approval from NEC Corporation. UNIVERGE, NEAX and Dterm are registered trademarks or trademarks to be registered of NEC Corporation.
MM0009/0304 NEAX 2000 IPS General Description TABLE OF CONTENTS Page CHAPTER 1 INTRODUCTION ...........................................................................................................1 UNIVERGE Architecture.......................................................................................................................................1 System Overview .......................................................................................................................................
MM0009/0304 LIST OF ILLUSTRATIONS Figure Title Page Figure 1-1 NEAX 2000 IPS...................................................................................................................................3 Figure 1-2 NEAX 2000 IPS System Overview....................................................................................................4 Figure 1-3 Example of Network Configuration of Remote PIM over IP ..........................................................
MM0009/0304 LIST OF TABLES Table Title Page Table 1-1 Technical Terms of NEAX 2000 IPS System ....................................................................................9 Table 2-1 Modules of NEAX 2000 IPS System ................................................................................................15 Table 3-1 D term Series i/D term IP Specifications and Accessories.....................................................................
INTRODUCTION CHAPTER 1 INTRODUCTION UNIVERGE Architecture UNIVERGETM is NEC’s IP architecture for unifying multimedia networks while enabling robust business solutions. UNIVERGE is an open and standards-based IP architecture, ensuring interoperability with other broadband media, IT equipment and business applications. It also enables seamless and mobile communication in a multi-network environment.
INTRODUCTION UNIVERGE Architecture CHAPTER 1 Page 2 MM0009/0304
INTRODUCTION This document provides an overview of the NEAX 2000 IPS (Internet Protocol Server) stored program control digital electronic PBX. An introduction to the technical characteristics is included, along with a description of available system applications.
INTRODUCTION DtermIP telephones are designed to provide a converged infrastructure at the desktop, with a 100 BASE-T Ethernet connection to the LAN and built-in hub for a PC connection to the telephone itself. The system can provide peer-to-peer connections between DtermIP telephones with voice compression, on a CCIS basis (CCIS over IP). IPS also provide Windows PC based softphone (Dterm SP30) to connect to LAN network and it provides IP enabled Dterm features without the telephone set.
INTRODUCTION Remote PIM over IP NEAX 2000 IPS can install a PIM at remote site through IP network. At the main site, the NEAX 2000 IPS is installed and the Remote PIM is installed at remote site. The main site controls call processing and service feature access for station users located both main and remote sites.
INTRODUCTION Migration Path For customers who are using the NEAX 7400 ICS M100MX*, the migration path is supplied. By replacing the existing MP card to the new IPS MP card, the NEAX 7400 ICS M100MX* can be upgraded to IP/TSW Hybrid System including new and enhanced service features introduced with the NEAX 2000 IPS.
INTRODUCTION Extended Application Processor (AP) Port Capacity The NEAX 2000 IPS provides a maximum of 256 AP ports and it is independent of the 512 ports for the Line/Trunk (LT), therefore, more AP cards such as T1/E1 digital link cards can be used in the system. Universal Slot One PIM provides 12 card slots for Line/Trunk (LT). Also, these card slots can be used for Application Processor (AP) cards without complicated limitation.
INTRODUCTION Software Architecture Built-in DRS (Device Registration Server) on MP The NEAX 2000 IPS incorporates DRS (Device Registration Server) on the MP. DRS provides Log-in/Logout management of DtermIP including Registration and Authentication. Also, the built-in DRS can be interworked with DHCP server to provide easy administration on IP address.
INTRODUCTION Technical Terms Table 1-1 Technical Terms of NEAX 2000 IPS System SYMBOL DESCRIPTION SYMBOL DESCRIPTION AMP Amplifier Trunk Card LC Line Circuit Card (for Single Line Telephone) AP00 SMDR/Hotel Application Card LDT LD Trunk Card BGM External Music Source for Dterm Back Ground Music Service LLC Long Line Circuit Card BRT Basic Rate Interface Trunk Card M10 Optical Interface Card CCH Common Channel Handler Card MAT Maintenance Administration Terminal CFT 6/10 Party Confe
INTRODUCTION Trunking Diagram This figure shows a typical trunking diagram of the NEAX 2000 IPS system.
SYSTEM CONFIGURATION CHAPTER 2 SYSTEM CONFIGURATION Module Configuration The NEAX 2000 IPS consists of Port Interface Modules (PIM) depending on the system configuration, and there are two types of PIMs; “Physical” PIM and “Virtual” PIM. The Physical PIM is a “hardware” PIM and is used to accommodate an MP, FPs, IP PADs, legacy LT an AP cards, and power supply units. One Physical PIM provides up to 64 ports.
SYSTEM CONFIGURATION Installation Methods The NEAX 2000 IPS provides three installation methods as follows: Floor Standing Installation Wall Mounting Installation 19-inch Rack Mounting Installation Floor Standing Installation In Floor Standing Installation, the NEAX 2000 IPS is comprised of up to 8 Port Interface Modules (PIMs).
SYSTEM CONFIGURATION Wall-mounting Installation The NEAX 2000 IPS can be wall-mounted with single or multiple PIM (MAX. 8) configuration.
SYSTEM CONFIGURATION 19-inch Rack-mounting Installation The NEAX 2000 IPS can be mounted in the IEC-standard 19-inch rack up to 4 PIMs.
SYSTEM CONFIGURATION Modules and Installation Hardware The NEAX 2000 IPS is comprised of up to 8 Port Interface Modules (PIMs). Modules (1) Port Interface Module (PIM) A PIM provides 13 card slots for common control, Line/Trunk (LT), and Application Processor (AP) cards. It also houses an AC/DC Power Supply (or DC/DC Power Supply), optional DC/DC Power Supply (for -48V), and batteries for protection from short-term (about 30 min.) power interruption.
SYSTEM CONFIGURATION Circuit Cards The circuit cards used for NEAX 2000 IPS are divided into the following three types. According to these card types, the mounting location of card and port allocation of the Time Division Switch are varied. Common Control Cards - Main Processor (MP) - Firmware Processor (FP) Line/Trunk (LT) Cards - IP PAD, Line Circuit (LC), Central Office Trunk (COT), Tie Line Trunk (LDT/ODT), PRI Trunk (PRT) etc.
SYSTEM CONFIGURATION Conditions for Maintenance MATWorX can be used as the maintenance program for NEAX 2000 IPS. Direct connection (RS-232C), Modem connection and LAN (TCP/IP) connection are available to connect to the MAT (Maintenance Administration Terminal). Conditions for DRS DRS = Device Registration Server The Dterm IP registration is executed by the DRS-System Based. The DRS-Network Based is not available for the Dterm IP registration. The DRS can be used as the Proxy server.
TERMINALS CHAPTER 3 TERMINALS A variety of terminal equipment may be connected to the NEAX 2000 IPS. The following equipment may be installed with the system.
TERMINALS Desk Console The SN716 Desk Console has an ergonomic design and provides full access to all PBX Console features. It connects to the NEAX 2000 IPS using the same circuit cards as the Dterm 75 Series terminals. The SN716 Desk Console operates on a switched-loop basis with a maximum of 6 Attendant loops terminating at each console on the associated Interface card. The Attendant uses these loops for answering, originating, holding, extending, and reentering calls.
TERMINALS Dterm Series i/Dterm IP Digital Multifunction Terminals The Dterm Series digital multifunction/multiline terminal is available in two colors to meet the needs of various users based on the features and types of communications each end user requires.
TERMINALS Dterm Series i/Dterm IP Lineup Dterm 2 (2-button Dterm) This Dterm Series Digital Multi-line Terminal is equipped with 8 dedicated Function keys (such as Hold, TRANSFER, ANSWER, SPEAKER, REDIAL, CONF, RECALL and FEATURE), 2 programmable Line/Feature keys (each with a two-color LED). 2 programmable keys are flexible and can be assigned to any outside line connected to the system, to another station line, or as a feature button.
TERMINALS Dterm Series i/Dterm IP Accessories Direct Station Selection (DSS) Console This Console is equipped with 60 programmable line keys (each with a two-color LED). These keys can be programmed as Direct Station keys, Function keys, or Line keys. The DCU-60 Console is available in two colors - Black (BK) and Ivory White (WH). Analog Port Adapter (APR) The Analog Port Adapter with Ringing (APR-U) provides an interface for installing single line telephones (SLTs), modems*.
TERMINALS term Figures of D term Series i/D IP * Dterm 2 (Black) is also supported. term Figure 3-2 D term Figure 3-3 D 2 (White) 4D (Black) * Dterm 8 (Black) is also supported.
TERMINALS * Dterm 8 D (Black) is also supported. term Figure 3-5 D 8D (White) * Dterm 16 D (Black) is also supported. term 16D (White) term 32D (White) Figure 3-6 D * Dterm 32 D (Black) is also supported.
TERMINALS * DSS Console (White) is also supported. Figure 3-8 DSS Console (Black) * Dterm 16LD (White) is also supported.
TERMINALS Figure 3-11 Ancillary Device Adapter (ADA) Figure 3-12 Computer Telephony Adapter (CTA-R) Figure 3-13 IP Adapter (IP-R) CHAPTER 3 Page 26 MM0009/0304
TERMINALS Dterm Series i/Dterm IP Specifications The specifications of the Dterm Series i/Dterm IP are shown in below.
TERMINALS Table 3-2 Combination Pattern of Optional Accessories to the Dterm Series i/ Dterm IP Combination Pattern 1 2 3 4 5 6 7 8 9 10 X : Available CHAPTER 3 Page 28 APR ADA X CTA-R IP-R X X X X X X X X MM0009/0304 X X X WM-R X X X X X X X X X X
TERMINALS Wireless System A mobile work force no longer has to be dependent on special technology. With personal telephone and Wireless Communication System, employees can travel throughout a multistored building or across a large industrial complex and continue to stay in constant touch with customers and colleagues. NEAX 2000 IPS has built-in wireless system for providing wireless communication, it can support up to 72 users.
TERMINALS (4) Department Stores and Hotels On the sales floor, the wireless communication service allows a clerk to check inventory for a customer or promptly call the manager. When holding an even or exhibition, or when changing the sales floor layout, the wireless service requires no cable laying or transfer, so telephone installation and removal are simple.
TERMINALS Personal Handyphone System (PHS) Personal Station (PS) The PS (Personal Station) incorporates the 32 Kbps ADPCM encoding technique and privacy function so that you can talk about even important matters in a noise-free, very clear voice. Since the PS is light-weight and compact in size, it can conveniently carried around. Here are specifications for the PS and its major functions. Specification of Personal Station Table 3-3 PHS Personal Station (PS) Specifications Item Specifications Frequency 1.
TERMINALS Cell Station (CS) Because of its small size, light weight and slenderness, the CS can be installed anywhere...the wall surface, the ceiling or behind the ceiling. In addition, its expansion or relocation can be smoothly performed. Followings are the specifications for the CS. Specification of Cell Station Table 3-4 2-Wired (U-Interface) Cell Station (CS) Specifications Item Specifications Radio Interface RCR STD-28 Ver.
TERMINALS 2-Wired Cell Station (CS) (U-Interface) Personal Station (PS) Figure 3-15 Cell Station (CS) and PHS Personal Station (PS) MM0009/0304 CHAPTER 3 Page 33
TERMINALS Personal Communication System (PCS) Personal Station (PS) The PS (Personal Station) incorporates the 32 Kbps ADPCM encoding technique and privacy function so that you can talk about even important matters in a noise-free, very clear voice. Since the PS is light-weight and compact in size, it can conveniently carried around. Here are specifications for the PS and its major functions.
TERMINALS Zone Transceiver (ZT) Because of its small size, light weight and slenderness, the ZT can be installed anywhere...the wall surface, the ceiling or behind the ceiling. In addition, its expansion or relocation can be smoothly performed. Followings are the specifications for the ZT.
TERMINALS 2-Wired Zone Transceiver (ZT) (U-Interface) Personal Station (PS) Figure 3-16 Zone Transceiver (ZT) and PCS Personal Station (PS) CHAPTER 3 Page 36 MM0009/0304
TERMINALS Dterm Softphone (SP30) This Dterm Softphone provides the Dterm IP features without the telephone set, and it works on the Windows PC connected to LAN network. You click the button on the picture, the button, lamp and LCD works like an actual telephone. In addition to making and answering calls operation, Dterm SP30 provides call logs for all incoming and outgoing calls the user has made or received, and a recording of live conversation. Dterm SP30 also provides telephone directory integration.
TERMINALS Subpanels and Functions Function Key Panel Displays lines and functions set for PBX and enables changing of button name and pop-up. Short Message Log Panel Displays transmission, reception and error logs of simple messages and lets user select a log to telephone or reply to a sender. Call Forward Settings Panel For setting or cancelling Call Forwarding-All Calls/Busy Line/ Don’t Answer/ Log Out for PBX.
OVERVIEW OF INSTALLATION AND MAINTENANCE CHAPTER 4 OVERVIEW OF INSTALLATION AND MAINTENANCE Installation Installation of Main Equipment The installation of the NEAX 2000 IPS is comprised of up to 8 Port Interface Modules (PIMs). A PIM provides 13 card slot for Common Control, Line/Trunk (LT), and Application Porcessors (AP) cards. It also houses an AC/DC Power Supply, DC/DC Power Supply (for -48V), and batteries for protection from short-term (about 30 minutes) power interruption.
OVERVIEW OF INSTALLATION AND MAINTENANCE Maintenance Trouble Reporting and Diagnosis The urgency of a fault is indicated by the MJ/MN lamp provided on the Power Card and optional external alarm indicator. System Administration System data, which varies from installation to installation and which is subject to continual change during service, is readily entered or changed from the Dterm or MAT (Maintenance Administration Terminal).
SPECIFICATIONS CHAPTER 5 SPECIFICATIONS System Capacity The following table shows the system capacity. Table 5-1 System Capacity (Single MP System) Item LT Card AP Card 2PIM (No. of Ports) 64 128 192 256 320 (No. of Cards) (No. of Ports) 12 24 36 48 60 (No. of Cards) 12 Note 9 Dterm (Lines) term D term IP/ D term IP INASET/ D Standard Long 8PIM 384 448 512 72 84 96 448 512 24 64 (No. of Channel) Analog Single Line Telephone (Lines) 7PIM Max.
SPECIFICATIONS Table 5-1 System Capacity (Single MP System) (Cont’d) Item 1PIM DTMF Sender DTMF Receiver SN716 Desk Console 2PIM 16 SN708 Digital Console (Australia) System Capacity 3PIM 4PIM 5PIM 6PIM Max. 32 circuits per system 32 8 7PIM 8PIM 8 (Production discontinued) SN709/712/741 Smart Console 8 (Production discontinued) Attendant Terminal (Dterm ATT Position) Max.
SPECIFICATIONS Table 5-1 System Capacity (Single MP System) (Cont’d) Note 4: Message Waiting Lamp is not available when the 4LLC is mounted in slot 08 to 10. Note 5: From FP 3300, maximum 256 PS can be accommodated to the system in addition to the maximum 512 LT ports. Ex: 400 Dterms + 100 CO Lines=500 LT Ports Total 650 Ports available 150 PSs Note 6: Total number of CS and IP-BS should be 128 or less.
SPECIFICATIONS IP Specifications Table 5-2 IP Specifications ITEM Voice Encoding IP PAD FAX Communication Feature SPECIFICATIONS G.729a G.723.1 (5.3 k/6.3 k) G.711 8/32 channels per card Automatically seized per call FAX Relay Method (T.30) FAX Relay Method (Path-through (G.711/G.726)) DTMF Signal Inter-office/Intra-office Signaling H.245 H.245 PROTIMS over IP CCIS over IP H.
SPECIFICATIONS Table 5-2 IP Specifications (Cont’d) ITEM PAD Control SPECIFICATIONS 0 dB to +16 dB (+2 dB increments) 0 dB to –16 dB (–2 dB increments) When using PN-8IPLA (IP PAD): 0 dB to +14dB (+2 dB increments) 0 dB to –14 dB (–2 dB increments) 0 dB to –16 dB (For North America) 0 dB to –12 dB (For other than North America) REMARKS Setting is available per Location No. For connection between DtermIPs For connection via the IPT card Note: When no 16VCT card is mounted, the CODEC type is fixed to G.
SPECIFICATIONS Line Conditions Table 5-3 Line Conditions DESCRIPTION SPECIFICATIONS Loop Resistance (including Telephone Set) Analog Standard Line Max. 600 ohms Analog Long Line Max. 2,500 ohms (DP 10pps), Max.1,700 ohms (DP 20pps) Max. 1,200 ohms (DTMF) Loop Resistance (including Opposite End Resistance) Central Office trunk Max. 1,700 ohms Max. 2,500 ohms Tie Line Trunk (Loop Dial) Note 3 Tie Line Trunk (E&M) Max.
SPECIFICATIONS Cell Station/Zone Transceiver Line Conditions Table 5-4 Cell Station/Zone Transceiver Line Conditions DESRIPTION SPECIFICATIONS Cell Station BS31 (for U-Interface) Max. 800 meters (2-wire), Max. 1,600 meters (4-wire) @-43V Note BS31 with AC Adapter Max. 5,000 meters Zone Transceiver (for Latin America) ZTII-S (for S-Interface) Max. 1,219 meters @-48V, Max. 975 meters @-45V ZTII-S with AC Adapter Max. 1,341 meters @-48V ZTII-U (for U-Interface) Max. 1,219 meters (2-wire), Max.
SPECIFICATIONS Dimension and Weight Table 5-7 Dimension and Weight DESCRIPTION SPECIFICATIONS DIMENSIONS (W × D × H; mm) Main Equipment PIM (Fully card-mounted) BASE BASE TRAY (for UL) Dterm 75 Series Dterm 8 Dterm 8D Dterm 16D Dterm 32D DSS Console Dterm Series i Dterm 2DT Dterm 4D Dterm 8 Dterm 8D Dterm 16D Dterm 16LD Dterm 32D DSS Console Dterm Series i (Russian display model) Dterm 8D-R Dterm 16D-R Dterm 32D-R Attendant Console SN709/712/741 Smart Console (Production discontinued) SN716 Desk Console