MD242C2 MD302C4 INSTALLATION & MAINTENANCE GUIDE
Index Warning, Caution ..........................................................................................................................English-1 Intended Use ................................................................................................................................English-2 Registration Information ...............................................................................................................English-3 Recommended use ............................................
TO PREVENT FIRE OR SHOCK HAZARDS, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE. ALSO, DO NOT USE THIS UNIT’S POLARIZED PLUG WITH AN EXTENSION CORD RECEPTACLE OR OTHER OUTLETS UNLESS THE PRONGS CAN BE FULLY INSERTED. REFRAIN FROM OPENING THE CABINET AS THERE ARE HIGH VOLTAGE COMPONENTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK, MAKE SURE POWER CORD IS UNPLUGGED FROM WALL SOCKET.
Intended Use The MD242C2/MD302C4 Color display is intended to be used for displaying and viewing of digital images for diagnosis by trained physicians. To guarantee the display performance as specified, it must only be used in conjunction with NEC approved display controllers. MD242C2/MD302C4 cannot be used for a life-support system. This device must not be used in digital mammography. This device is designed for exclusive interconnection with IEC 60601-1-1 certified equipment.
English Registration Information Declaration Declaration of the Manufacturer NEC Display Solutions Europe GmbH declares that the product listed is in conformity with the essential requirements and provisions of the Council Directive 93/42/EEC, including the amendments of the Council Directive 2007/47/EC, and conforms to the applicable clauses of the following standards: Means of Conformity Device Classification: Applicable Rules: Product Name: Model Number: UMDNS Code: Class I, non-measuring function An
Recommended use Safety Precautions and Maintenance FOR OPTIMUM PERFORMANCE, PLEASE NOTE THE FOLLOWING WHEN SETTING UP AND USING THE LCD MONITOR: WARNING: Do not modify this equipment without authorization of the manufacturer. WARNING: To disconnect this product from the mains supply disconnect the mains plug from the socket outlet. WARNING: To avoid risk of electric shock, this equipment must only be connected to a supply mains with protective earth. WARNING: No modification of this equipment is allowed.
b) This model is equipped with an integrated front sensor and ambient light sensor complying with the IEC 62563-1 standard requirements for measurement devices with a calibration traceable to a primary standards laboratory. Therefore, these sensors can be re-calibrated using external luminance and illuminance meters as a reference, which were calibrated following country specific legal obligations for metrological control.
Contents Your new NEC monitor box* should contain the following: • Monitor with tilt/swivel/pivot/height adjust stand • Power Cord • Video Signal Cable (DVI-D cable)*2 • Video Signal Cable (DisplayPort cable)*4 • Video Signal Cable (Mini DisplayPort to DisplayPort cable)*3 • USB Cable • Quick Reference Guide • CD-ROM x 2 • Screw (x 4) (to mount the monitor to a flexible arm (page 11)) CD-ROM x 2 Mini-DisplayPort to DisplayPort cable*3 Power Cord*1 Screws Quick R eferenc e Guide Quick
To connect the LCD monitor to your system, follow these instructions: NOTE: Make sure to read “Recommended Use” (page 4) before installation. In order to display the maximum resolution, a display controller that can output a resolution of 1920 x 1200 for MD242C2 and 2560 x 1600 for MD302C4 is needed. MD302C4 only: The monitor must be installed or carried by two or more people. 1. Turn off your computer. 2.
4. Connect all cables to the appropriate connectors (Figure C.1). When using the USB cable, connect the B type connector to the USB upstream port on the right back side of the monitor and the A type connector to the downstream port on the computer (Figure C.1a). If using the cord from a USB device, plug into one of the downstream ports of the monitor. NOTE: Incorrect cable connections may result in irregular operation, damage display quality/components of the LCD module and/or shorten the module’s life.
Power Cord D-SUB Cable HDMI Cable*1 Mini DisplayPort Cable DVI Cable DisplayPort Cable*1 DVI-D Cable DisplayPort Cable USB Cable (MD242C2) USB Cable Figure C.3 (MD302C4) 7. Slide down the cable cover (Figure D.1). 8. Connect one end of the power cord to the AC inlet on the back of the monitor and the other end to the power outlet. NOTE: Please refer to the Caution section of this manual for proper selection of an AC power cord. Figure D.1 9.
Screen Rotation Before rotating, the screen must be raised to the highest level and tilt to avoid knocking the screen on the desk or pinching your fingers. Disconnect all cables. To raise the screen, place hands on each side of the monitor and lift up to the highest position (Figure RL.1). To rotate the screen, place hands on each side of the monitor and turn clockwise from Landscape to Portrait or counterclockwise from Portrait to Landscape (Figure R.1).
English Flexible Arm Installation This LCD monitor is designed for use with a flexible arm. To prepare the monitor for alternate mounting purposes: • Follow the instructions provided by the manufacturer of the monitor mount. • To meet the safety requirements, the monitor must be mounted to an arm that supports the weight of the monitor. See page 26-27 for details. Remove the monitor stand before mounting. Remove the Monitor Stand for Mounting To prepare the monitor for alternate mounting purposes: 1.
Controls OSD (On-Screen Display) control buttons on the front of the monitor function as follows: To access the OSD menu, press the MENU button. The Key Guide appears pressing any button when not in the OSD control menu. NOTE: The OSD must be closed in order to change the signal input. 6 7 E D 2 3 4 A B C 5. Control Buttons 1 KEY GUIDE 1 The Key Guide appears on the screen when the OSD control menu is accessed. The Key Guide will rotate when the OSD control menu is rotated.
• Set the OSD language before using OSD functions. • Use the control keys (LEFT/RIGHT or UP/DOWN or EXIT) to access the “LANGUAGE SELECTION” menu. • Press the LEFT/RIGHT or UP/DOWN buttons to select the desired OSD language. • To exit from this OSD menu, press the EXIT button. NOTE: Setting the OSD language is only necessary upon initial setup. The OSD language will stay the same until changed by the user (See page 15). Luminance LUMINANCE Adjusts the overall image and background screen luminance.
AUTO FINE (Analog input only)* This function automatically and periodically adjusts the “FINE” setting for change in signal condition. This function adjusts approximately every 33 minutes. EXPANSION Sets the zoom method. FULL: The image is expanded to full screen regardless of the resolution. ASPECT: The image is expanded without changing the aspect ratio. OFF: The image is not expanded. CUSTOM: Refer to the Advanced OSD menu for detailed instructions.
Change USB upstream input associated with the current display input, 1 or 2. When connecting a computer to each of the upstream ports, the monitor's USB downstream ports can be used by selecting this setting for the current input signal. You can change the active display and upstream USB port combination by using the Input button (see page 12). You can set the USB selection for each input signals in Advanced menu (see page 23).
OSD LOCK OUT This control completely locks out access to all OSD control functions. When attempting to activate OSD controls while in the Lock Out mode, a screen will appear indicating the OSD controls are locked out. There are two types of OSD LOCK OUT: OSD LOCK OUT with no control: To activate the OSD Lock Out function, press SELECT, then “RIGHT” button and hold down simultaneously. To deactivate the OSD Lock Out, press SELECT, then “RIGHT” button and hold down simultaneously while in the OSD menu.
Choose the Picture mode which is the most suitable for the type of displayed content. These are the available modes: MEDICAL, Gamma 2.2 and PROGRAMMABLE1. • Each PICTURE MODE includes PRESET, LUMINANCE, WHITE, Color Gamut (RED, GREEN, BLUE), GAMMA, BLACK, UNIFORMITY, AMB.LIGHT COMP., RESPONSE IMPROVE and (6-AXIS ADJUST) settings. You can change these settings in Tag1 and Tag2 on the Advanced OSD. The type of PRESET PRESET PURPOSE MEDICAL Factory setting.
Quick screen QA test function Allows the monitor to display an internal test pattern similar to AAPM TG18-QC, without using an external signal source. A quick overall visual evaluation as well as an inspection of the gray levels according to DICOM is available with this built-in method. - If the monitor is connected with a video signal source (computer): Make sure that no OSD menu is displayed, then press the RESET button for more than 3 seconds or press the RESET button twice.
• When both OSD and Key Guide are off, push the “RESET” and “EXIT” buttons two times simultaneously. • You will see the Advanced OSD. This menu is larger than the normal OSD. • Push the “EXIT” button. To make an adjustment, ensure that the tag is highlighted, then press “SELECT”. To move to another tag, press “EXIT”, then press “LEFT” or “RIGHT” to highlight another tag. Tag1 PICTURE MODE Selects one of two possible PICTURE MODES.
Tag2 Tag3 RED GREEN BLUE Adjusts color gamut. When the selected settings are outside of the LCD gamut, the indicator on the OSD will turn magenta. UNIFORMITY*1 This function electronically compensates the slight variations in the white uniformity level that may occur across the display area of the screen. These variations are a characteristic of LCD panel technology. This function evens out the luminance uniformity of the display. Selectable UNIFORMITY levels are OFF, LOW and HIGH.
Compensates for image degradation caused by using a long cable. A lower number produces less compensation. Compensates for disturbed image caused by using a long DisplayPort cable. DIGITAL LONG CABLE*2 (DP/Mini-DP There are 2 possible settings, 1 and 2. Setting “2” produces a better result, but may input only) reduce display colors. The default setting is “1”. Tag4 LONG CABLE CAPABILITY* (Analog input only) R-H.POSITION: Adjusts the position of the red component of the image.
AUTO BLACK LEVEL*, *1 Automatically adjusts the black level. Any adjustment requires the image to have black (Analog input only) portions. Press “SELECT” to activate AUTO ADJUST. Tag5 BLACK LEVEL* (Analog input only) Adjusts the RGB black level by input signal level. VIDEO LEVEL (HDMI input only) NORMAL: For computer setting. Displays all input signals of 0-255 steps. EXPAND: For audio-visual equipment setting. Expands input signals of 16-235 steps to 0-255 steps.
Tag6 Tag7 Some video formats may require different scanning modes in order to best display the image. ON: Image size is larger than what can be displayed. The image edge will appear cropped. Approximately 95% of the image will be shown on the screen. OFF: Image size stays within the display area. The whole image is displayed on the screen. AUTO: Auto setting. USB SELECTION USB UP Stream Port Selection for DP/HDMI/DVI-D/D-SUB.
OSD LOCK OUT*1 This control completely locks out access to all OSD control functions. When attempting to activate OSD controls while in the Lock Out mode, a screen will appear indicating the OSD controls are locked out. There are two types of OSD LOCK OUT: OSD LOCK OUT with no control: To activate the OSD Lock Out function, press SELECT, then “RIGHT” button and hold down simultaneously. To deactivate the OSD Lock Out, press SELECT, then “RIGHT” button and hold down simultaneously while in the OSD menu.
OSD ROTATION: Sets the OSD display direction. AUTO: The OSD rotates automatically when the monitor is rotated. OSD ROTATION is set to AUTO by default. LANDSCAPE: The OSD appears in landscape orientation. PORTRAIT: The OSD appears in portrait orientation. MAIN IMAGE ROTATION: Sets the main image display direction. AUTO: The image automatically rotates according to the orientation of the monitor. IMAGE ROTATION is set to AUTO by default. LANDSCAPE: The image is not rotated. PORTRAIT: The image is rotated.
Specifications - MD242C2 Monitor Specifications MD242C2 Monitor Notes LCD Module 61.1 cm/24.1 inches 61.1 cm/24.1 inches 1920 x 1200 (Landscape) 1200 x 1920 (Portrait) Active matrix; thin film transistor (TFT) liquid crystal display (LCD); 0.270 mm dot pitch; 350 cd/m2 white luminance; 180 cd/m2 calibrated luminance; 1000:1 contrast ratio (typical). Digital RGB DisplayPort Complies with Standard V1.1a, applicable to HDCP DVI 0.7 Vp-p/75 ohm Separate sync.TTL level Positive/Negative Composite sync.
Monitor Specifications MD302C4 monitor Notes LCD Module 75.6 cm/29.8 inches 75.6 cm/29.8 inches 2560 x 1600 Active matrix; thin film transistor (TFT) liquid crystal display (LCD); 0.251 mm dot pitch; 340 cd/m2 white luminance; 180 cd/m2 calibrated luminance; 1000:1 contrast ratio (typical). Digital RGB DisplayPort Complies with Standard V1.1a, applicable to HDCP DVI (HDCP) HDMI (HDCP) Depends on display card used.
Features DisplayPort: DisplayPort is designed to be the future-ready, scalable solution for high performance digital display connectivity. It enables the highest resolutions, the fastest refresh rates and deepest color depths over standard cables. DVI-D: The digital-only subset of DVI ratified by the Digital Display Working Group (DDWG) for digital connections between computers and displays. As a digital-only connector, analog support is not provided off a DVI-D connector.
No Picture • The signal cable should be completely connected to the display controller/computer. • The display controller should be completely seated in its slot. • The monitor does not support a DisplayPort converter signal. • Monitor power switch and computer power switch should be in the ON position. • Make certain the computer is not in a power-saving mode (touch the keyboard or mouse). • Check to make sure that a supported mode has been selected on the display controller or system being used.
STAND-ALONE CALIBRATION Stand alone calibration can recalibrate the display without using a computer by the integrated front sensor or connecting an external sensor. There are 4 (MD242C2) or 5 (MD302C4) functions in STAND-ALONE CALIBRATION. • Self Calibration: Calibrates the integrated front sensor based on the USB color sensor*1. Alternatively, manually adjust the integrated front sensor with an external near range color analyzer reference, which is traceable to a primary standards laboratory.
Calibrates the integrated front sensor based on the USB color sensor*1. Or to manually adjust the integrated front sensor with an external near range color analyzer reference, which is traceable to a primary standards laboratory. All PICTURE MODES are updated when Self Calibration is performed. NOTE: AUTO CALIB. mode requires connecting the USB color sensor to the sensor port*1. EXPERT CALIB. mode requires an external near range color analyzer. 1.
[EXPERT CALIB.] An external near range color analyzer, which is traceable to a primary standards laboratory, is required for this method. 5. The procedure will ask for the external near range color analyzer to be placed on the center of the display panel. Place the external near range color analyzer in the center of the display panel, then press SELECT. 6. The measument screen will be displayed.
6. After copying Display A information, the target luminance will be stored and displayed in the OSD of Display B. The target value is not adjustable (Figure C.5). The white points of Display A and Display B should match. Press SELECT if the copy result is satisfactory. If the copy result is unsatisfactory, press “RESET”. 7. When you want to confirm the white point of Display B, remove the USB color sensor from source Display A and place in the center of Display B (Figure C.2).
DICOM Measurement DICOM PART14 can be performed by using the integrated front sensor. 1. To show the CALIBRATION menu, select the STAND ALONE CALIBRATION in the advanced menu (page 25). 2. Use “LEFT” or “RIGHT” to select DICOM MEASURE in the MODE selection (Figure D.1). 3. Select the GAMMA that you want to measure and press SELECT. NOTE: This function is effective only if GAMMA (Advanced menu Tag1) is DICOM or PROGRAMMABLE1. 4. After the DICOM MEASURED RESULT message appears (Figure D.2).
6. After the CALIBRATION SUCCEEDED message appears (Figure AS.4), press SELECT. You can set DATE and TIME by using control keys, and press SELECT. 7. To end the calibration mode, press EXIT. Figure AS.3 Figure AS.4 Illuminance meter Figure AS.5 English-35 English 5. Input the value measured at 1, and press SELECT (Figure AS.3). When not having measured, press SELECT without changing the value.
Manufacturer’s Recycling and Energy Information NEC DISPLAY SOLUTIONS is strongly committed to environmental protection and sees recycling as one of the company’s top priorities in trying to minimize the burden placed on the environment. We are engaged in developing environmentallyfriendly products, and always strive to help define and comply with the latest independent standards from agencies such as ISO (International Organisation for Standardization) and TCO (Swedish Trades Union).