© NEC Corporation 2019 61
Click the View Module Calibration Coefficients button.
Result: Pop-up message opens (see Figure 89).
Figure 89: Flash Module after loading Module Calibration Data
Click Save Calibration Coefficients to Receiving Card.
The pop-up message, that the data has been successfully stored to the Receiving
cards, will appear (see Figure 90).
Result: The screen with the exchanged Pixel cards should look calibrated now.
Figure 90: Flash Module after saving Module Calibration Data
Click on Save to HW button and go back to main window by clicking X button.
Repeat all steps for Screen 2. Click on the Return button to be able to select Screen
2 and re-open Module Flash