User's Manual
70
7.46. “ TEMP_HYSTERESIS ” Control procedure
7.46.1. TEMP_ HYSTERESIS Control
CMD Data1 Data2 Data3 Data4 Data5
Command
(0xF5)
Target
(0x88)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x3A)
Value
Command (0xF5) : Start bit
Target (0x88) : Set bit
Monitor ID (0x00) : Default value -> 0x00
CMD (0xFE) : command data
Parameter(0x3A) : ‘ TEMP_HYSTERESIS ’ parameter
Value: 2 ~ 20 (range)
7.46.2. Current TEMP_ HYSTERESIS state read
CMD Data1 Data2 Data3 Data4
Command
(0xF4)
Target
(0x89)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x3A)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x3A) : ‘TEMP_ HYSTERESIS ’ parameter
CMD Data1
Command
(0xF1)
Value
Command (0xF1) : Start send bit
Value : Current TEMP_ HYSTERESIS getting value
2 ~ 20 (range)