User's Manual

53
7.30. OFFMINUTE Control procedure
7.30.1. OFFMINUTE Control (Power OFF time)
CMD Data1 Data2 Data3 Data4 Data5
Command
(0xF5)
Target
(0x88)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x27)
Value
Command (0xF5) : Start bit
Target (0x88) : Set bit
Monitor ID (0x00) : Default value -> 0x00
CMD (0xFE) : command data
Parameter(0x27) : OFFMINUTE parameter
Value: 0 ~ 59 (range)
7.30.2. Current OFFMINUTE state read
CMD Data1 Data2 Data3 Data4
Command
(0xF4)
Target
(0x89)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x27)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x27) : OFFMINUTE parameter
CMD Data1
Command
(0xF1)
Value
Command (0xF1) : Start send bit
Value : Current OFFMINUTE getting value
0 ~ 59 (range)