7.18. “ USERBLUE ” Control procedure
7.18.1. USERBLUE Control
CMD Data1 Data2 Data3 Data4 Data5
Command
(0xF5)
Target
(0x88)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x11)
Value
Command (0xF5) : Start bit
Target (0x88) : Set bit
Monitor ID (0x00) : Default value -> 0x00
CMD (0xFE) : command data
Parameter(0x11) : ‘ USERBLUE ’ parameter
Value: 0 ~ 100 (range)
7.18.2. Current USERGREEN state read
CMD Data1 Data2 Data3 Data4
Command
(0xF4)
Target
(0x89)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x11)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x11) : ‘USERBLUE’ parameter
CMD Data1
Command
(0xF1)
Value
Command (0xF1) : Start send bit
Value : Current USERBLUE getting value
0 ~ 100 (range)