User's Guide

1. Installing Internal Optional Devices
Express5800/R120f-2M Users Guide
54
Chapter 2 Preparations
13. Make sure that the heat sink is installed on a level with the motherboard.
Note
If the heat sink is not level, remove it, and then install it again.
The following probably causes the heat sink not to be level:
The CPU is not positioned correctly.
All screws are not completely tightened.
Do not move the secured heat sink.
14. Install an additional fan unit provided with additional CPU board.
See Chapter 2 (1.15 Additional / Redundant Fan Unit) for how to install an additional fan unit.
15. Continue to install or remove internal optional devices, mount and connect the server, and turn it on.
16. Run BIOS Setup Utility (SETUP) to confirm the following settings. See Chapter 2 (1. System BIOS) in
"Maintenance Guide".
Advanced Processor Configuration Processor Information
[CPU ID]
[L2 Cache RAM]
[L3 Cache RAM]
1.11.3
Replacement / Removal
Important
Do not remove any CPU unless it is failed.
To remove the heat sink from the CPU, first turn the heat sink to the left
and right lightly to make sure that the heat sink can be apart from the CPU.
Removing the heat sink with it adhering to the CPU may cause the CPU
and/or CPU socket to be defected.
If you fail to mount protective cover and dummy cover to the slot where
CPU is removed, the cooling effect in the server will deteriorate. It may
cause a malfunction of the server.
To remove CPU, reverse the installation procedure.
Perform the following steps if using the server with the CPU being removed.
1. Mount the protective cover to CPU socket.
2. Secure the dummy cover to the slot with four screws.
3. Remove the additional fan unit.
4. Mount the fan cover.
Perform the following steps after replacing or removing the CPU.
1. Run BIOS Setup Utility (SETUP) to confirm the following settings. See Chapter 2 (1. System BIOS) in
"Maintenance Guide".
Advanced Processor Configuration Processor Information
[CPU ID]
[L2 Cache RAM]
[L3 Cache RAM]