Reference Guide

54
2.2.30 getTestAlertStatus
Syntax:
dscli getTestAlertStatus Component Target
Description:
Obtains the state of an alert test. The parameter supported according to the kind of BMC is different.
Options:
Component
Specify the name, the MAC address of LAN port that BMC uses, or the GUID of the managed
component.
Target
Specify an alert receiver. See 2.2.29 testAlert.
Output:
Displays the state of the alert test. One of the following test states is displayed.
TEST_UNKNOWN: Unknown status
TEST_TESTING: Now Alerting
TEST_SUCCESS: Alert test is succeeded.
TEST_ABORT: Alert test is failed.
TEST_CALL_FAILED: Alert test is failed. (Dial up error)
TEST_TIMEOUT: Alert test is failed. (Timeout)
TEST_ERROR: Alert test is failed (Other reason)
While an alert is being sent, the alert state is displayed as follows:
TEST_TESTING
2.2.31 getServerStatus
Syntax:
dscli getServerStatus Component
Description:
Displays the status of a specified managed component.
Confirms the managed component status by component monitoring function.
Options:
Component
Specify the name, the MAC address of LAN port that BMC uses, or the GUID of the managed
component.
Output:
Displays the managed component status as following.
ERROR: Error
WARNING: Warning
UNKNOWN: Unknown or connection error
DC-OFF: DC-OFF
NORMAL: Normal
NO_MONITORING: Out of monitoring