Appendix

Event ID
(hex digit)
Severity
Description
Log
Alert
Summary
Deal Method
0434
(400001B2)
Information
[Address Type 3 ] Background Initialization was queued.
R
0435
(400001B3)
Information
[Address Type 3 ] Power Save Mode of Logical Drive was
changed.
RO
0436
(400001B4)
Information
[Address Type 3 ] SSD Cache Drive was created.
RO
M
SSD Cache Drive Created
None
0437
(400001B5)
Information
[Address Type 3 ] SSD Cache Drive Capacity was changed.
RO
M
SSD Cache Drive Capacity
Changed
None
0438
(800001B6)
Warning
[Address Type 3 ] Failed to change Logical Drive parameters
automatically.
RO
M
Auto Change Logical Drive
Parameters Failed
Please restart raidsrv service.
0501
(400001F5)
Information
[Address Type 1 ] Battery was detected.
R
0502
(800001F6)
Warning
[Address Type 1 ] Battery was disconnected.
RO
MA
Battery Disconnect
Please check the Battery. If some kind of problem
happen to the Battery repeatedly, please replace it.
0503
(400001F7)
Information
[Address Type 1 ] Battery was replaced.
R
0504
(400001F8)
Information
[Address Type 1 ] The temperature of Battery is normal.
RO
M
Battery Temperature
Normal
None
0505
(800001F9)
Warning
[Address Type 1 ] The temperature of Battery is high.
RO
M
Battery Temperature High
Please check the Battery. If some kind of problem
happens to the Battery repeatedly, please replace it.
0506
(800001FA)
Warning
[Address Type 1 ] The voltage of Battery is low.
RO
M
Battery Voltage Low
Please check the Battery. If some kind of problem
happens to the Battery repeatedly, please replace it.
0507
(800001FB)
Warning
[Address Type 1 ] A Fatal Error happened to Battery.
RO
MA
Battery Fatal
Please replace the Battery.
0508
(800001FC)
Warning
[Address Type 1 ] The Battery state is unstable.
RO
0509
(400001FD)
Information
[Address Type 1 ] The voltage of Battery is normal.
RO
M
Battery Voltage Normal
None
0510
(800001FE)
Warning
[Address Type 1 ] Battery Refresh required.
RO
M
Battery Refresh Required
Please start the Battery Refreshing.
0511
(400001FF)
Information
[Address Type 1 ] Flash Backup Unit was detected.
R
0512
(80000200)
Warning
[Address Type 1 ] Flash Backup Unit was disconnected.
RO
MA
Flash Backup Unit
Disconnect
Please check the Flash Backup Unit. If some kind of
problem happens to the Flash Backup Unit repeatedly,
please replace it.
0513
(40000201)
Information
[Address Type 1 ] Flash Backup Unit was replaced.
R
0514
(40000202)
Information
[Address Type 1 ] The temperature of Flash Backup Unit is
normal.
RO
M
Flash Backup Unit
Temperature Normal
None
9