Appendix

Event ID
(hex digit)
Severity
Description
Log
Alert
Summary
Deal Method
0406
(C0000196)
Fatal
[Address Type 3 ] Initialization failed.
RO
MA
Initialization Failed
Try to initialize again. If it fails again, verify if there are
a
ny other error/warning messages regarding RAID
system. If you found the other messages, deal with the
problem for the messages. After you deal with the
problem, try to initialize again. If you don't find any other
messages regarding RAID system, the RAID Controller
may be faulty. Collect log files with the NEC Product Info
Collection Utility(collect.exe tool) and contact your
service representative.
0407
(40000197)
Information
[Address Type 3 ] Initialization was stopped.
R
0409
(40000199)
Information
[Address Type 3 ] Consistency Check was started.
R
0410
(4000019A)
Information
[Address Type 3 ] Consistency Check completed.
R
0411
(C000019B)
Fatal
[Address Type 3 ] Consistency Check failed.
RO
MA
Consistency Check Failed
Verify if there are any other error/warning messages
regarding RAID system. If you found the other
messages, deal with the problem for the messages.
After you deal with the problem, execute the
Consistency Check again. If you don't find any other
messages regarding RAID system,
the RAID Controller
may be faulty. Collect log files with the NEC Product Info
Collection Utility(collect.exe tool) and contact your
service representative.
0412
(4000019C)
Information
[Address Type 3 ] Consistency Check was stopped.
R
0413
(C000019D)
Fatal
[Address Type 3 ] Data Inconsistency was detected in
Logical Drive by Consistency Check and corrected.
RO
MA
Data Inconsistency Error
Corrected
Please execute Consistency Check again when the load
of the system is low. If the error does not occur on the
second time of Consistency Check, the Physical Device
does not have any problems. If the same error occurs,
please replace the Physical Device for the preventive
maintenance (please be sure to ask NEC customer
service before the replacement to identif
y which
Physical Device has a failure). After replacing the
Physical Device, restore the backup data to the Logical
Drive.
0415
(4000019F)
Information
[Address Type 3 ] Logical Drive was created.
R
0416
(400001A0)
Information
[Address Type 3 ] Logical Drive was deleted.
R
0417
(400001A1)
Information
[Address Type 3 ] The Cache Mode of Logical Drive was
changed. (Value : %1)
%1 : Changed value
*1
RO
M
Cache Mode Changed
None
7