Appendix
Event ID
(hex digit)
Severity
Description
Log
Alert
Summary
Deal Method
0218
(C00000DA)
Fatal
[Address Type 1 ] A Fatal Firmware Error happened to RAID
Controller. %1
RO
MA
RAID Controller Fatal
Firmware Error
Please replace the RAID Controller.
0219
(400000DB)
Information
[Address Type 1 ] RAID Controller property was changed.
RO
0220
(800000DC)
Warning
[Address Type 1 ] SAS wide port lost link on SAS Expander.
RO
MA
SAS Port link lost
Verify if the Mini-SAS cable between a RAID controller
and a drive bay is connected properly. If the connection
is correct, replace the Mini-SAS cable. If the same error
persists after r
eplacing the cable, replace the RAID
controller or the expander board. If you can not solve
this issue by these measures, contact your service
representative and gather system information with NEC
Product Info Collection Utility(collect.exe tool) and send
him/her the information.
0221
(400000DD)
Information
[Address Type 1 ] SAS wide port restored link on SAS
Expander.
RO
M
SAS Port link restored
None
0222
(800000DE)
Warning
[Address Type 1 ] Failed to get RAID system information to
change Logical Drive(s) parameters automatically.
RO
M
Get RAID System
Infomation Failed
Please restart raidsrv service.
0223
(800000DF)
Warning
[Address Type 1 ] RAID System is unstable by inconsistency
in the Status of Physical Device.
RO
M
RAID System unstable
Please check whether problem does not occur to the
configuration of the RAID System. If the Physical Device
of which the RAID System is not configured exists
though it is Online, please replace the RAID Controller
and the Physical Device.
0224
(400000E0)
Information
[Address Type 1 ] The temperature of RAID Controller is
normal.
RO
M
RAID Controller
Temperature is Normal
None
0225
(800000E1)
Warning
[Address Type 1 ] The temperature of RAID Controller is
high.
RO
M
RAID Controller
Temperature is High
Please check if cooling unit is working normally and the
ambient temperature is in normal condition (10 - 40
degree C). If you do not find any problem and this
warning message persists repetitively, please replace
the RAID controller.
0226
(C00000E2)
Fatal
[Address Type 1 ] The temperature of RAID Controller is
abnormal.
RO
MA
RAID Controller
Temperature is Abnormal
The RAID controller halted because its temperature
reached fatal level. Please check if cooling unit is
working normally and the ambient temperature is in
normal condition (10 -
40 degree C). If you will not find
any problem and this fatal message persists
repetitively, please replace the RAID controller.
0301
(4000012D)
Information
[Address Type 2 ] Physical Device is Online.
RO
M
Physical Device Online
None
0302
(4000012E)
Information
[Address Type 2 ] Physical Device is Ready.
RO
M
Physical Device Ready
None
0303
(4000012F)
Information
[Address Type 2 ] Physical Device is Hot Spare.
RO
M
Physical Device Hot Spare
None
0304
(C0000130)
Fatal
[Address Type 2 ] Physical Device is Failed.
RO
MA
Physical Device Failed
Please replace the Physical Device.
4