Appendix
Event ID
(hex digit)
Severity
Description
Log
Alert
Summary
Deal Method
0605
(8000025D)
Warning
[Address Type 5 ] An error happened to the Power Supply
Unit of Enclosure.
RO
MA
Enclosure Power Supply
Unit Error
Check if the POWER FAULT LED on a power unit in the
SAS JBOD Enclosure is lit up. Replace the power unit in
the SAS JBOD Enclosure if the POWER FAULT LED is lit
up. Otherwise collect log files with the NEC Product Info
Collection Utility and contact your service
representative. Refer
to the Maintenance Guide that
comes with the server for how to use the NEC Product
Info Collection Utility.
0606
(8000025E)
Warning
[Address Type 6 ] An error happened to the Fan Unit of
Enclosure.
RO
MA
Enclosure Fan Unit Error
Check if the POWER FAULT LED or FAN FAULT LED on a
power unit in the SAS JBOD Enclosure is lit up. Replace
the power unit in the SAS JBOD Enclosure if the POWER
FAULT LED or the FAN FAULT LED is lit up. Otherwise
collect log files with the NEC Product Info Collection
Utility and c
ontact your service representative. Refer to
the Maintenance Guide that comes with the server for
how to use the NEC Product Info Collection Utility.
0607
(4000025F)
Information
[Address Type 4 ] The temperature of Enclosure is Normal
level.
RO
MA
Enclosure Temperature
Normal
None
0701
(400002BD)
Information
[Address Type 1 ] The Configuration was cleared.
RO
M
Configuration Cleared
None
0702
(400002BE)
Information
raidsrv Configuration
[CTRL:%1(ID=%2)] Vendor Product Firmware Version
[LD:%3(ID=%4)] RAID:RAIDlevel PD:X,Y,Z
(count of LD
STS:Status
[PD:%5(ID=%6
] Vendor/Model Firmware Version STS:Status
PWR:Power Status
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Logical Drive
%4 : ID of Logical Drive
%5 : Number of Physical Device
%6 : ID of Physical Device
X, Y, Z : Number of Physical Device used in Logical Drive.
There is not the STS of PD when the device type is not HDD
or HDD(SSD).
O
0801
(C0000321)
Fatal
It became unable to manage the RAID System due to a fatal
error on the operating system.
RO
MA
Operating System Fatal
Error
Please solve the fatal error on operating system. This
event is reported by insufficient free memory space,
insufficient free disk space or any other causes. Please
refer Universal RAID Utility User's Guide for detail.
*1 : This item may not include in log message by the type of RAID Controller
11