Appendix

Event ID
(hex digit)
Severity
Description
Log
Alert
Summary
Deal Method
0515
(80000203)
Warning
[Address Type 1 ] The temperature of Flash Backup Unit is
high.
RO
M
Flash Backup Unit
Temperature High
Please check the Flash Backup Unit. If some kind of
problem happens to the Flash Backup Unit repeatedly,
please replace it.
0516
(80000204)
Warning
[Address Type 1 ] The voltage of Flash Backup Unit is low.
RO
M
Flash Backup Unit Voltage
Low
Please check the Flash Backup Unit. If some kind of
problem happens to the Flash Backup Unit repeatedly,
please replace it.
0517
(80000205)
Warning
[Address Type 1 ] A Fatal Error happened to Flash Backup
Unit.
RO
MA
Flash Backup Unit Fatal
Please replace the Flash Backup Unit.
0601
(80000259)
Warning
[Address Type 4 ] A Warning Error happened to Enclosure.
RO
M
Enclosure Warning
Check if the FAULT LED on an adapter in the SAS JBOD
Enclosure is lit up. Replace the adapter in the SAS JBOD
Enclosure if the FAULT LED is lit up, otherwise collect log
files wi
th the NEC Product Info Collection Utility and
contact your service representative. Refer to the
Maintenance Guide that comes with the server for how
to use the NEC Product Info Collection Utility.
0602
(C000025A)
Fatal
[Address Type 4 ] A Fatal Error happened to Enclosure.
RO
MA
Enclosure Fatal
Check if the FAULT LED on an adapter in the SAS JBOD
Enclosure is lit up. Replace the adapter in the SAS JBOD
Enclosure if the FAULT LED is lit up, otherwise collect log
files with the NEC Product Info Collection U
tility and
contact your service representative. Refer to the
Maintenance Guide that comes with the server for how
to use the NEC Product Info Collection Utility.
0603
(8000025B)
Warning
[Address Type 4 ] The temperature of Enclosure is Warning
level.
RO
MA
Enclosure Temperature
Warning
Check if the POWER FAULT LED or FAN FAULT LED on a
power unit in the SAS JBOD Enclosure is lit up. If the
either of LEDs is not lit up, check if ambient
temperature is beyond normal condition (5 -
35 degree
C). If the ambien
t temperature is in normal condition,
collect log files with the NEC Product Info Collection
Utility and contact your service representative. Refer to
the Maintenance Guide that comes with the server for
how to use the NEC Product Info Collection Utility.
0604
(C000025C)
Fatal
[Address Type 4 ] The temperature of Enclosure is Fatal
level.
RO
MA
Enclosure Temperature
Fatal
Check if the POWER FAULT LED or FAN FAULT LED on a
power unit in the SAS JBOD Enclosure is lit up. If the
either of LEDs is not lit up,
check if ambient
temperature is beyond normal condition (5 -
35 degree
C). If the ambient temperature is in normal condition,
collect log files with the NEC Product Info Collection
Utility and contact your service representative. Refer to
the Maintenance G
uide that comes with the server for
how to use the NEC Product Info Collection Utility.
10