Configuration Guide
CONFIGURATION GUIDE – NEC Express5800/R120f-2E Storage-Rich
NEC Corporation Revision 3.0 – April 17, 2015 6
Model
R120e-2E
Redundant Power Supply
Optional, hot plug
Power Supply
1 to 2 x 800 Watt 80 PLUS® Platinum certified hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Power
Consumption
Max. Config, Idling
247 VA / 245 Watt
244 VA / 243 Watt
246 VA / 244 Watt
Max. Config, Operating
605 VA / 601 Watt
664 VA / 660 Watt
730 VA / 725 Watt
Acoustic Noise
(Sound Pressure
Level)
3
Max. Config, Idling
53.0dB
53.0dB
53.0dB
Max. Config, Operating
61.1 dB
61.1 dB
62.0 dB
Dimensions (W x D x H )
448.0 x 683.8 x 87.2 mm / 17.6 x 26.9 x 3.4 in (2U)
Weight (Minimum / Maximum)
18 kg / 31 kg, 39.68 lbs. / 68.34 lbs.
Temperature, Relative Humidity
(non-condensing)
Operating: 10° to 40° C
4
/ 50°
4
to 104° F, 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
Regulatory and Safety
FCC, UL, CB, CE, BSMI, UL(Mexico), KC, RoHS
Operating Systems
Microsoft® Windows Server® 2008 Standard (x86)
Microsoft® Windows Server® 2008 Enterprise (x86)
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
Red Hat Enterprise Linux 6.5 or later (x86)
5
Red Hat Enterprise Linux 6.5 or later (x86_64)
5
VMware ESXi™ 5.1 Update 2
6
VMware ESXi™ 5.5 Update 2
6
VMware ESXi™ 6.0
6
1
An optional drive cage is required to install more than 12 hard drives.
2
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
3
Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating
environment.
4
Operable up to 35°C (95°F) when N8181-126 Redundant Fan Kit is installed and any of
N8150-474/-490/-477/-478/-483/-486/-513 SAS HDD is installed in the rear HDD cage.
5
For Linux support, contact our sales representative or go to the NEC website at:
http://www.nec.com/global/prod/express/linux/index.html
6
5GB or more memory is required.