Installation Guide (Linux) Express5800 Series NEC ESMPRO Manager Ver. 6.00 Chapter 1 Introduction Chapter 2 Installation Chapter 3 Uninstallation Chapter 4 Appendix E6.
Contents Contents.................................................................................................................................................................2 Notations Used in This Document ..........................................................................................................................3 Notations used in the text.....................................................................................................................
Notations Used in This Document Notations used in the text In addition to safety-related symbols urging caution, 3 other types of notations are used in this document. These notations have the following meanings. Important Indicates critical items that must be followed when operating software. Note Indicates items that must be confirmed when operating software. Tips Indicates information that is helpful to keep in mind.
Abbreviations of Operating Systems Windows Operating Systems (OS) are referred to as follows.
Trademarks EXPRESSCLUSTER is a registered trademark of NEC Corporation. Microsoft, Windows, Windows Vista, Windows Server are registered trademarks or trademarks of Microsoft Corporation in the United States and other countries. VMware, VMware ESXi are registered trademarks or trademarks of VMware, Inc. in the United States and other countries. Intel and Intel vPro are registered trademarks or trademarks of Intel Corporation in the United States and other countries.
Warnings and Additions to This Document 1. Unauthorized reproduction of the contents of this document, in part or in its entirety, is prohibited. 2. This document is subject to change at any time without notice. 3. Do not make copies or alter the document content without permission from NEC Corporation. 4. If you have any concerns, or discover errors or omissions in this document, contact your sales representative. 5.
External Libraries This product contains libraries (“external libraries”) provided by the third party suppliers ("suppliers"). Assume and agree these libraries' license documents and NOTICE files before using this product.
♦ External Libraries and their Copyright activation Copyright©Sun Microsystems, Inc. annogen Copyright©The Codehaus. antlr Developed by jGuru.com, http://www.ANTLR.org and http://www.jGuru.
asm-attrs Copyright©INRIA, France Telecom backport-util-concurrent Copyright©Distributed Computing Laboratory, Emory University bcprov-jdk Copyright©The Legion Of The Bouncy Castle (http://www.bouncycastle.org) c3p0 Copyright©Machinery For Change, Inc. cglib Copyright©cglib dom4j Copyright©MetaStuff, Ltd. DWR Copyright©Joe Walker ehcache Copyright©Luck Consulting Pty Ltd Flot Copyright©IOLA and Ole Laursen ForceRedraw Copyright©Pascal Beyeler Hibernate Copyright©Red Hat Middleware, LLC.
libxml2 Copyright©Daniel Veillard. All Rights Reserved. mail Copyright©Sun Microsystems, Inc. msvcp90 Copyright©Microsoft msvcr90 Copyright©Microsoft OpenSAML Copyright©Internet2. OpenSSL Copyright©The OpenSSL Project prototype.js Copyright©Sam Stephenson sblim cim-client http://sourceforge.net/apps/mediawiki/sblim/index.php?title=CimClient snmp4j Copyright © 2003-2014, SNMP4J.org. All right reserved.
NEC ESMPRO Manager Ver. 6.00 General Description This chapter explains NEC ESMPRO Manager. 1. Introduction 2. About Downloading Latest NEC ESMPRO Describes about Downloading Latest NEC ESMPRO. 3. System Requirements Describes about the need environment of NEC ESMPRO Manager.
1. Introduction Read this document so as to gain an adequate understanding of the contents. The contents in this document are intended for users who fully understand features and operations of OS related to this utility. If you want to know operations of OS, or if there is any unclear point, see the online help of each OS. NEC ESMPRO Manager is a software designed for reducing operational management costs by remotely managing servers. NEC ESMPRO Manager has the following features.
2. About Download of Latest NEC ESMPRO See the following URL for NEC ESMPRO information. You can download the latest version of NEC ESMPRO from URL. http://www.58support.nec.co.jp/global/download/index.
3. System Requirements NEC ESMPRO Manager requires the following hardware and software: 3.1 PC for Management Important About product license NEC ESMPRO Manager can be used on a single OS per license. • Hardware - Machine A computer on which OS supported by NEC ESMPRO Manager can be installed - CPU Core2 Duo 1.80GHz or higher, or equivalent compatible processor is recommended. - Memory Memory required for running OS plus 1GB or more (2GB or more is recommended.
3.2 Managed server A server to be managed by NEC ESMPRO Manager is as follows: Baseboard Management Controller (BMC) About the managed server integrated BMC, see "Appendix D Managed Components Summary" in " NEC ESMPRO Manager Ver.6 Setup Guide". Note The required environment varies depending on the connection type with the managed server. See "Chapter1 3.3 Requirements for Connection between PC for Management and Managed Server".
3.3 Requirements for connection between PC for Management and managed server Provide an environment in accordance with the connection type to be used. LAN connection - TCP/IP network • Do not use a cross cable to connect PC for Management and managed server. Note • If you use the managed server integrated BMC, LAN port that BMC uses depends on the type of BMC. Some BMC uses standard LAN port. Other BMC uses a Management LAN Port.
3.4 Notes on managed servers and network devices This section explains particular notes on managed servers and network devices. Use of network switch / router If the managed server installed BMC that uses a standard LAN port or loaded Advanced Remote Management Card, and there is network switch / router between PC for Management and the managed servers, set the network switch / router to receive Gratuitous ARP. See each document of the switch / router about how to set it.
- If the teaming is set with channel bonding on Linux, please add "mode" and "primary" definition to the line of /etc/modprobe.conf or /etc/modules.conf as following.
NEC ESMPRO Manager Ver. 6.00 Installation This chapter explains installation of NEC ESMPRO Manager. 1. Before Installation Describes about necessary setting before NEC ESMPRO Manager installation. 2. Installation Describes about installation procedure of NEC ESMPRO Manager. 3. After Installation Describes about necessary setting after NEC ESMPRO Manager installation.
1. Before Installation Be sure to read this page before installing NEC ESMPRO Manager. ♦ Prerequisites Before installing NEC ESMPRO Manager, check the followings: See “chapter1 3.1PC for Management” to check the system requirement of NEC ESMPRO Manager server. Note Login to Linux as root user, or get authority of root by "su" command. NEC ESMPRO Manager installer exists on the following directory in EXPRESSBUILDER: "EXPRESSBUILDER revision"/lnx/pp/esmpro_sm. (ex.
2. Installation This page describes fresh installation and update installation of NEC ESMPRO Manager. Be sure to read "Before Installation" and install this product. 2.1 Installation procedure ♦ Install NEC ESMPRO Manager 1. Save NEC ESMPRO Manager installer into any directory, and uncompress it. 2. Move to the directory containing the NEC ESMPRO Manager installer. The following is an example of installation into /usr/local/bin: cd /usr/local/bin 3. Start NEC ESMPRO Manager installer.
♦ Update install NEC ESMPRO Manager Note If NEC ESMPRO Manager Ver. 5.0 or later has already been installed, you can update it to this version. 1. Save NEC ESMPRO Manager installer into any directory, and uncompress it. 2. Move to the directory containing the NEC ESMPRO Manager installer. The following is an example of installation into /usr/local/bin: cd /usr/local/bin 3. Start the NEC ESMPRO Manager installer. The NEC ESMPRO Manager will be installed under /opt/nec/es_manager. sh esmpro.sh 4.
3. After Installation ♦ Login When the installation of NEC ESMPRO Manager completes, check that you can login to it. 1.Access to the following address on a Web browser on the web client. http://"the computer name installed NEC ESMPRO Manager":"HTTP connection port number"/esmpro/ This is an example of address to access with HTTP connection port "21112" from the web browser on PC for Management. http://localhost:21112/esmpro/ * If EXPRESSCLUSTER system is installed, access to the following address.
When the login succeeds, the following window appears: Note The area on which commands, such as [AlertViewer], [Tools] are displayed is called [Header Menu]. Use these commands on [Header Menu] to operate NEC ESMPRO Manager. ♦ Setting environment You can change the optional setting of NEC ESMPRO Manager. Click [Environment] on [Header menu] to check the setting. For details, see the online help.
♦ SSL If you need to login to NEC ESMPRO Manager using SSL, you must change the setting of NEC ESMPRO Manager. Perform the procedure that is necessary in order to use SSL with NEC ESMPRO Manager as follows: 1.Create a key The Key tool is needed for creating the key using with SSL. The Key tool is contained in JRE. Create the key as follows: /opt/nec/es_manager/jre/bin/keytool -genkey -alias tomcat -keyalg RSA Some messages are displayed with dialog style.
2.Change the setting of NEC ESMPRO Manager. Edit the server.xml file to enable SLL. The server.xml is in the directory containing NEC ESMPRO Manager. Move to the conf directory that there is a server.xml file. cd /opt/nec/es_manager/wbserver/conf Open the server.xml file with an editor tool, search the description of which is specified port number 8443, and delete the comment form "". Modify the port number if you need.
♦ Changing the port number You can change the available port number after installation of NEC ESMPRO Manager. An example of address to access in HTTP connection port "21112". 1. Stop NEC ESMPRO Manager. ♦ Stop procedure 1. /etc/rc.d/init.d/esmweb stop 2. /etc/rc.d/init.d/esmsm stop 2. Edit the port number in the "server.xml" setting file. Edit the "server.xml" file to change a port number. The "server.
♦ Coexistence with Tomcat When NEC ESMPRO Manager and Tomcat are installed same computer, the application software installed later will not be running correctly. In this case, you can avoid it by the following way. 1. If NEC ESMPRO Manager has started, stop NEC ESMPRO Manager. ♦ Stop procedure 1. /etc/rc.d/init.d/esmweb stop 2. /etc/rc.d/init.d/esmsm stop 2. If Tomcat service has started, stop the service. 3. Edit the server port number and connector port number in the "server.xml" setting file.
NEC ESMPRO Manager Ver. 6.00 Uninstallation This chapter explains uninstallation of NEC ESMPRO Manager. 1. Uninstallation Describes about uninstallation procedure of NEC ESMPRO Manager.
1. Uninstallation This page describes how to uninstall NEC ESMPRO Manager. 1.1 Uninstallation procedure 1. Save NEC ESMPRO Manager installer into any directory, and uncompress it. 2. Move to the directory containing NEC ESMPRO Manager installer. The following is an example of installation into /usr/local/bin: cd /usr/local/bin 3. Start NEC ESMPRO Manager uninstaller. NEC ESMPRO Manager will be installed under /opt/nec/es_manager. sh esmpro.sh 4. Confirmation for uninstallation.
NEC ESMPRO Manager Ver. 6.00 Appendix 1. Notes Describes about note when using NEC ESMPRO Manager. 2. Port numbers / Protocols Describes about the port numbers and port Protocols NEC ESMPRO Manager uses.
1. Notes Check the following points after installing NEC ESMPRO Manager: 1.1 NEC ESMPRO Manager ♦ Installation After NEC ESMPRO Manager is updated, NEC ESMPRO Manager on the web browser may display incorrectly. Take the following steps to avoid it. [Internet Explorer 10,11] 1. Click [Tools]. 2. Select [Delete Browsing History]. 3. Select the checkbox for [Temporary Internet Files]. 4. Click [Delete] button. [Firefox(Linux)] 1. Click [Edit]. 2. Click [Preferences] menu. 3. Select [Advanced]. 4.
You must logout from the web browser that is login to NEC ESMPRO Manager before NEC ESMPRO Manager is updated. After NEC ESMPRO is updated during login, some error may be displayed on any web browser. When the error is displayed, you must close web browser that is login to NEC ESMPRO Manager and restart NEC ESMPRO Manager. ♦ Stop procedure 1. /etc/rc.d/init.d/esmweb stop 2. /etc/rc.d/init.d/esmsm stop ♦ Start procedure 1. /etc/rc.d/init.d/esmsm start 2. /etc/rc.d/init.
♦ Shutdown OS NEC ESMPRO Manager commands NEC ESMPRO Agent Extension or NEC ExpressUpdate Agent on the managed component to shutdown OS. The order of priority for the shutdown function is NEC ESMPRO Agent Extension and NEC ExpressUpdate Agent. ♦ IPMI information collection While a managed server is tuned OFF, some records of management controller information and FRU (Field Replaceable Unit) information cannot be read in.
♦ In case of key-in failure on the remote console During DOS boot or access to the removable media immediately after the managed server is power switch is turned ON, data cannot be keyed in from the remote console or the keyed data display may be delayed. Remote Console is realized by using SOL function of IPMI conformity and the Serial Redirection function of BIOS.
♦ Coexistence of NEC ESMPRO Manager with DianaScope Agent or NEC ESMPRO Agent Extension on the same server If the managed server is installed Advanced Remote Management Card or EXPRESSSCOPE Engine series (BMC uses exclusive LAN port (management LAN port)), NEC ESMPRO Manager can manage the server itself installed. If the managed server is installed BMC that uses the standard LAN port, NEC ESMPRO Manager on the managed server cannot manage itself.
♦ Display of the Information of server state/constitution In case that NEC ESMPRO Manager has been updated from Ver. 5.23 and below, the display of the selected item on [Information of server state/constitution] may take long time with the hardware constitution of the managed server. Perform the followings in this case: Change the "Update Interval" value of "Automatically update display" setting from 5 second s (default value) to 60 seconds.
♦ Replacing a managed server After replacing monitored server, even if the server name and IP address remains the same, delete the corresponding server icon and execute AutoRegistration. Otherwise, the replaced server is not recognized and the server status and the configuration information is not correctly displayed.
♦ The default setting of EXPRESSSCOPE Engine 3 You can change BMC Configuration Information from [BMC Setting] of NEC ESMPRO Manager. For details of [BMC Setting], see the online help of NEC ESMPRO Manager. Refer to EXPRESSSCOPE Engine 3 User’s Guide about difference between NEC ESMPRO Manager's default value and a value which 'Configuration Initialization' function will set. ♦ Standby BMC Configuration Setting It may take a few minutes to set the Standby BMC Configuration.
1.2 NEC ExpressUpdate ♦ Installation of NEC ExpressUpdate Agent To use the function of "Installing NEC ExpressUpdate Agent", following configurations are necessary. *1 Change following configurations with the user belongs to Administrators group. *2 See"Chapter4 2 Appendix Port numbers / Protocols" for network ports and protocols which this function uses.
Windows Server 2008 R2 1) Configure Windows Firewall. Select [File and Printer Sharing] on [Control Panel] - [System and Security] - [Windows Firewall] [Allow a program or feature through Windows Firewall] and click [OK]. 2) Configure UAC. [Control Panel] - [User Accounts] - [User Accounts] - [Change User Account Control settings]-Select [Never notify]. Windows Server 2008 R2 Core 1) Configure Windows Firewall.
1.3 Managed Servers ♦ Setting Windows Firewall If Windows Firewall is enabled, communication with the management machine will be interrupted and the system will not work correctly. To use NEC ESMPRO Manager Windows Firewall enabled, open the required ports.
♦ CUI Remote Console after Windows boot If the managed server does not support SOL, Remote Console of SAC of Windows cannot be executed via LAN. To execute CUI remote console function of SAC screen after Windows boot, select [Server]-[Console Redirection] and change [ACPI Redirection] to [Enable] on BIOS Setup Utility screen of the managed server. When [ACPI Redirection] is set to [Enable] on BIOS Setup Utility screen, CUI remote console function cannot be executed after POST.
1.4 BMC Configuration ♦ BMC Configuration tool Among BMC configuration information tools there are some tools which cannot be used to setup NEC ESMPRO Manager. NEC MWA Agent cannot be used. If DianaScope or NEC ESMPRO Agent Extension is not stored in EXPRESSBUILDER DVD-ROM, [A setup of a system management] stored in the same EXPRESSBUILDER DVD-ROM cannot be used. The Console-less function of EXPRESSBUILDER can be used only when ESMPRO is stored in the same EXPRESSBUILDER DVD-ROM.
2. Advanced Remote Management Card If the managed server has been installed Advanced Remote Management Card, BMC may not immediately obtain IP address after BMC is set to obtain IP address by DHCP. Please turn the managed server AC-OFF and then AC-ON because BMC try to obtain IP address whenever the managed server is turned AC-ON. ♦ Port that BMC uses In case that Linux on the managed server uses port 623, NEC ESMPRO Manager cannot communicate with BMC that uses standard LAN port.
1.5 Web client ♦ Language setting on Web browser NEC ESMPRO Manager and Web client needs to be the same OS language. Do not change your browser language setting. ♦ Operation from two or more browsers NEC ESMPRO Manager cannot be operated using two or more browser windows by one Web client. When you use the browser which has tabbed browsing, NEC ESMPRO Manager cannot be operated using two or more tab.
♦ Note on using Internet Explorer If you login to NEC ESMPRO Manager from Web client using Internet Explorer for a long time, according to Internet Explorer restriction (for detail, see Microsoft Knowledge Base 830555), memory usage of Internet Explorer on Web client will increase. (About 10MB a day at maximum.) So, do following processes if you use it for a long time after login from Web client. - Logout Web client regularly. The increased memory by Internet Explorer restriction will be released by logout.
2. Port numbers / Protocols NEC ESMPRO Manager uses the following port numbers and protocols. In case of two-way protocol, upper arrow shows that connection starts, and lower arrow shows that connection turns. In case of port No. unknown, unused port is used to start connection. [Web Client <->PC for Management] Web Client Function Component Management/ monitoring web browser PC for Management Protocol Port No. /Direction Unknown TCP -> <- Port No.
Scheduled Running Search of NEC ExpressUpdate Agent, Universal RAID Utility NEC ExpressUpdate Agent, Universal RAID Utility NEC ExpressUpdate Agent, Universal RAID Utility event monitoring NEC ESMPRO Manager Unknown NEC ESMPRO Manager Unknown NEC ESMPRO Manager Unknown NEC ESMPRO Manager 21112 Remote installation of NEC ExpressUpdate Agent NEC ESMPRO Manager (When managed server's OS is Windows type) Unknown Unknown Remote installation of NEC ExpressUpdate Agent NEC ESMPRO Manager (When managed
[PC for Management -> EM Card] PC for Management Function Component Port No. Protocol /Direction Port No.