Installation Guide
5. Setting Up Windows Server 2008
Express5800/R120e-1M, R120e-2M Installation Guide (Windows)
212
Chapter 1 Installing Windows
(2) Using N8104-128
Using N8104-128 with the server, iSCSI Offload Engine and EnablePMTUBHDetect must be disabled.
Follow the procedure below to set it.
1. Double-click the Broadcom Control Suite icon on the Control Panel window.
Broadcom Advanced Control Suite starts.
2. Set Filter to ALL VIEW, select Broadcom BCM57711 NetXtreme II 10 GigE # xx under
Explorer View the Adapter xx (BCM57711 A0) - Port x.
3. Tab on Configurations at the right side screen and then expand Resource Reservations.
4. Click the [Configure] button on the Click the button to configure.
The Hardware and Resource Configuration Wizard appears.
5. Remove a checkmark from [iSCSI] under Protocols, if checked.
Select [Next], and then click the [Apply] button.
6. When the following message appears, select [Yes].
7. Complete steps 2 to 6 for each N8104-128 network adapter.
Then, close the Broadcom Advanced Control Suite.
8. Insert EXPRESSBUILDER DVD into the optical disk drive.
If Autorun Menu appears, close the menu.
Tips
EXPRESSBUILDER DVD is unnecessary if Starter Pack was installed from
Internal Flash Memory. Proceed to the next step.
9. Double-click BhdDisabled.vbs in the following folder.
• When using EXPRESSBUILDER DVD:
EXPRESSBUILDER DVD:\002\win\winnt\ws2008\lan\bcom\ws2008x86\lan
• If Starter Pack was installed from Internal Flash Memory:
System drive:\StartPKG\ws2008\lan\bcom\ws2008x86\lan
10. When the following message appears, click [OK].
11. Eject EXPRESSBUILDER DVD from the optical disk drive, and then restart the system.
Setup is now complete.
Black Hole Router Detect Disable Completed, Reboot the system
Applying the changes will temporarily interrupt the network connection.
The process may take several minutes and the connection will resume
afterwards.
Do you want to continue?