User's Guide

2. System BIOS Setup
Express5800/R120d-2M Users Guide
130
Chapter 3 Setup
2.4
Cases that Require Configuration
Only if a case applies to any of following cases, use the SETUP utility to change a parameter which was
configured as factory setting. Other than cases described below, do not change the settings. A list of SETUP
parameters and factory settings are described in Chapter 2 (1. System BIOS) in "Maintenance Guide".
Category Description To be changed Remark
Basic Change date and time
Main System Date
Main System Time
Configurable on OS
On/Off NumLock on power
ON
Boot Bootup Numlock State
On/Off the function to
display the NEC logo during
POST
Boot Quite Boot Disabled
By pressing the <Esc> key,
prevent the display of the
logo.
Memory Add or change DIMM
Advanced Memory
Configuration Memory Retest
Yes
After rebooting, Memory
Retest changes No
automatically.
Use memory RAS feature
Advanced Memory
Configuration Memory RAS
Mode change to RAS mode
Some of RAS features may
not be used depending on
DIMM configuration.
Optional
board
Disable Option ROM Scan
of installed option board
Advanced PCI Configuration
PCI Device Controller and Option
ROM Settings PCIXX Slot
Option ROM Enabled
XX is PCI slot number of the
option board
Boot Change the boot order of
devices
Boot Boot Option Priorities
Change the boot priority
When you use
EXPRESSBUILDER, set
CD/DVD to the highest
priority.
Use remote power on
function (via modem)
Advanced Advanced Chipset
Configuration Wake On Ring
Enabled
Use remote power on
function (via RTC alarm)
Advanced Advanced Chipset
Configuration Wake On RTC
Alarm Enabled
Use console redirection
feature
Advanced Serial Port
Configuration Console
Redirection Setting Change
respective setting.
Security Set a password
Security Administrator
Password Enter a password
Security User Password
Enter a password
If password is set, a
message to enter password
is displayed at next time
SETUP is launched.
Restrict bootup by entering
password
Security Password on Boot
Enabled
Can be selected when
password is set.
UPS
Powerlink
When the server is supplied
with power from UPS,
always turn on the power.
Server Power Control
Configuration AC-LINK
Power On
If it is turned off by using
POWER switch, leave it
OFF even when UPS
supplies power.
Server Power Control
Configuration AC-LINK Last
State
Keep the power OFF even
when UPS supplies power.
Server Power Control
Configuration AC-LINK Stay
off