Maintenance Manual
1. POST Error Message
Express5800/R120d-1M, R120d-2M Maintenance Guide
107
Chapter 3 Appendix
Error Message
Cause
Solution
B278 PCI Slot 1D - PCIe Link Speed
Error
Link Speed error was detected
on PCI Slot 1D.
Contact your sales representative.
C000 The error occurred during
fan sensor reading.
An error was detected while
reading fan sensor.
C010 The error occurred during
temperature sensor reading
An error was detected while
reading temperature sensor.
C011 System Temperature out of
the range.
A temperature abnormality was
detected.
It is possible that a fan has failed or is clogged.
Contact your sales representative.
C020 The error occurred during
voltage sensor reading.
An error was detected while
reading voltage sensor.
Contact your sales representative.
C021 System Voltage out of the
range.
A system voltage abnormality
was detected.
C040 SROM data read error
An error was detected while
reading data on SROM.
C061 1st SMBus device Error
detected.
An error was detected on 1st
SM Bus.
C062 2nd SMBus device Error
detected.
An error was detected on 2nd
SM Bus.
C063 3rd SMBus device Error
detected.
An error was detected on 3rd
SM Bus.
C064 4th SMBus device Error
detected.
An error was detected on 4th
SM Bus.
C065 5th SMBus device Error
detected.
An error was detected on 5th
SM Bus.
C066 6th SMBus device Error
detected.
An error was detected on 6th
SM Bus.
C067 7th SMBus device Error
detected.
An error was detected on 7th
SM Bus.
C068 8th SMBus device Error
detected.
An error was detected on 8th
SM Bus.
C101 BMC Memory Test
Failed.
An error was detected on BMC. Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.
C102 BMC Firmware Code
Area CRC check Failed.
C103
BMC core hardware failure.
C104 BMC IBF or OBF check failed.
An error was detected while
accessing BMC.
C105 BMC SEL area full.
There is not enough space to
store the system event log.
Start up Offline Tools (
Chapter 1, 9. Offline Tools
)
and delete the event logs.
C10C BMC update firmware
corrupted.
An illegality was detected while
updating BMC firmware.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.
C10D Internal Use Area of BMC FRU
corrupted.
An illegality was detected in
FRU containing the device
information.
C10E BMC SDR Repository empty.
An error was detected on BMC
SDR.
C10F IPMB signal lines do not
respond.
Failure of Satellite Management
Controller was detected.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.
C110 BMC FRU device failure.
An error was detected in FRU
that contains device
information.
C111 BMC SDR Repository failure.
Failure was detected in SROM
that stores the SDR.
C112 BMC SEL device failure.
Device failure was detected in
BMC SEL.
C113 BMC RAM test error.
An error was detected in BMC
RAM.
C114 BMC Fatal hardware error.
A hardware error was detected
in BMC.