Setup Guide

NEC ESMPRO Manager Ver.5 Setup Guide
72
"NEC ExpressUpdate"
--"Updates via NEC ExpressUpdate Agent"
Select "Registration" to manage the component using NEC ExpressUpdate.
--"Updates via Management Controller"
Select "Registration" to manage the component using Management Controller.
"Management controller management (Common)"
--"Management"
If NEC ESMPRO Manager managed the "Management controller" on the managed component,
select "Registration".
--"Management Type"
Select "BMC".
--"Authentication Key"
Enter the "authentication key" that you set in the "BMC configuration information" of the managed
component.
"Management controller management (LAN)"
--"Current IP Address"
If you have set both "IP Address1" and "IP Address2", specify the IP address you want to use for
connection.
--"Failover"
"Failover" is a function to continue communication by changing to the other IP address if
communication with the current IP address encounters an error. This setting is valid only when both
"IP Address1" and "IP Address2" have been set.
Determine whether to enable/disable the "Failover" function.
--"IP Address 1"
Enter the IP address that is specified on LAN1 of the BMC configuration for the managed
component.
--"Subnet Mask1"
Enter the subnet mask that is specified on LAN1 of the BMC configuration for the managed
component.
--"IP Address2"
Enter the IP address that is specified on LAN2 of the BMC configuration for the managed
component.
--"Subnet Mask2"
Enter the subnet mask that is specified on LAN2 of the BMC configuration for the managed
component.
The following screen shows an example.