User's Guide

1. Installing Internal Optional Devices
Express5800/R120d-1E User’s Guide
78
Chapter 2 Preparations
(1) When using the optional controller (N8103-160)
For details, refer to the manual that comes with optional RAID Controller (N8103-160).
Important
You must avoid static electricity to work with the procedure below. For
details, refer to Chapter 2 (1.2 Anti-static Measures).
Do not change the mode to hibernate when building a RAID System.
Note
When installing an optional RAID Controller, start the BIOS Setup utility, select
PCI Configuration from the Advanced menu, and then make sure that the
parameter of PCI Slot xx ROM (xx is PCI slot number) is set to Enabled.
When connecting a RAID Controller, set the boot priority to 8th or higher in the
Boot menu of the BIOS Setup utility. If the setting is 9th or lower, the
configuration menu for RAID Controllers cannot be launched.
Important
Do not change the mode to hibernate when building a RAID System.
1.12.4
Removal
To remove a riser card, reverse the installation procedure. Hold the card firmly and remove it. When removing
it, have another person hold the server so that the server does not move.
If needed, run SETUP utility, and then specify the boot order from the Boot menu. For details about the Boot
menu, refer to Chapter 2 (1. System BIOS) in "Maintenance Guide".
If using the server with the PCI card in slot #1A removed, attach the RAID card fixing bracket to the slot.
If using the server with the PCI card in slot #1B and/or #1C removed, attach the blank cover that comes with
the riser card to the slot.