User's Guide
2. BIOS Setup Utility (SETUP)
Express5800/R120d-1E User’s Guide
125
Chapter 3 Setup
2.4
Cases that Require Configuration
Only if a case applies to any of following cases, use SETUP to change a parameter which was configured as
factory setting. Other than cases described below, do not change the settings. A list of SETUP parameters
and factory settings are described in Chapter 2 (1. System BIOS) in "Maintenance Guide".
Category Description Setting of parameter Remark
Change date and time Configure date and time
Main System Date
Main System Time
Configurable on OS
On NumLock on power ON
Boot Bootup Numlock State
On
Basic
Off the function to display
the NEC logo during POST
Boot Quite Boot Disabled
By pressing the <Esc> key,
prevent the display of the
logo.
Memory configure after add
or change DIMM
Advanced Memory
Configuration Memory Retest
Yes
After rebooting, Memory
Retest changes No
automatically.
Memory
Use memory RAS feature Change to RAS mode
Advanced Memory
Configuration Memory RAS
Mode
You can select Mirroring,
Lock Step, or Sparing.
Optional
board
Disabled Option ROM that
installed RAID Controller
board
Advanced PCI Configuration
PCI Device Controller and Option
ROM Settings PCI Slot n
Option ROM Disabled
n is PCI slot number of the
RAID Controller
Change the boot order of
devices
Change the boot priority
Boot Boot Option Priorities
When you use
EXPRESSBUILDER, set
CD/DVD to the highest
priority.
Use remote power on
function (from modem)
Advanced Advanced Chipset
Configuration Wake On Ring
Enabled
Use remote power on
function (from RTC alarm)
Advanced Advanced Chipset
Configuration Wake On RTC
Alarm Enabled
Boot
Control from HW console
terminal
Change respective setting
Advanced Serial Port
Configuration . Console
Redirection Settings
Set a password to restrict
operation of SETUP Utility
Set a password
Security Administrator
Password
Security User Password
if you set password, you
havet to enter password
when starting SETUP
Utility..
Security
Set a password to restrict
Boot
Security Password On Boot
Enabled
You can select this
parameter after you set
password.
When the server is supplied
with power from UPS,
always turn on the power.
Server Power Control
Configuration AC-LINK Power
On
If it is turned off by using
POWER switch, leave it
OFF even when UPS
supplies power.
Server Power Control
Configuration AC-LINK Last
State
UPS
Powerlink
Keep the power OFF even
when UPS supplies power.
Server Power Control
Configuration AC-LINK Stay
off