User's Guide
35
An SSD Cache Disk Array icon indicates the status of SSD Cache Disk Array.
Icon
Meaning
Description
SSD Cache Disk Array
- Normal
All the SSD Cache Drives you have created, all the member Physical Devices
operate normally. No failures have not been detected by the RAID Controller.
SSD Cache Disk Array
- Warning
One or more Physical Devices in the warning condition exis
t in the SSD
Cache Disk Array.
SSD Cache Disk Array
- Fatal
One or more Physical Devices in the warning or fatal condition exist in the
SSD Cache Disk Array.
Logical Drive
The Logical Drive node exists in the Disk Array node. A Logical Drive node equals a Logical Drive, and shows the
number, status and RAID Level of the Logical Drive.
[Icon] LD #<Number> [<Status>] <RAID Level>
Item
Description
<Number> Indicates the management number (logical address) of the Logical Drive in the Universal
RAID Utility.
<Status> Indicates the status of the Logical Drive.
<RAID Level> Indicates the RAID Level of the Logical Drive.
A Logical Drive icon indicates the status of the Logical Drive.
Icon
Meaning
Description
Logical Drive - Normal The Logical Drive operates normally.
Logical Drive - Warning Because the Logical Drive contains one or more Physical Devices with Status
being Failed, the redundancy of the Logical Drive is lost or degraded.
Logical Drive - Fatal Because the Logical Drive contains one or more Physical Devices with Status
being Failed, the Logical Drive is offline and accessing to the Logical Drive is
disabled.
A RAID10/RAID50/RAID60 Logical Drive consists of more than one Disk Array according to
the type of the RAID Controller. Such Logical Drive nodes are located in more than one Disk
Array nodes.
SSD Cache Drive
The SSD Cache Drive node exists in the SSD Cache Disk Array node. An SSD Cache Drive node equals an SSD
Cache Drive, and shows the number and status of the SSD Cache Drive.
[Icon] LD #<Number> [<Status>] SSD Cache
Item
Description
<Number> Indicates the management number (logical address) of the SSD Cache Drive in the
Universal RAID Utility.
The number starts from 1 for HDD Logical Drive and SSD Cache Drive.
<Status> Indicates the status of the SSD Cache Drive.