User's Guide

34
Battery
If the RAID Controller has the Battery, the RAID Controller node has a Battery node. A Battery node and icon
shows the status of Battery.
[Icon] Battery [<Status>]
Item
Description
<Status> Indicates the status of the Battery installed in the RAID Controller.
Icon
Meaning
Description
Battery - Normal The Battery operates normally.
Battery - Warning The RAID Controller detects any problem of the Battery.
Disk Array
If there are some Logical Drive in the RAID Controller, the RAID Controller node has the Disk Array nodes
included the Logical Drives. The Disk Array node equals a Disk Array, and shows the number of the Disk Array.
The Logical Drives you have created, all Physical Devices as the members of the Logical Drives, and Dedicated
Hot Spares you have assigned to the Logical Drives exist in the Disk Array node.
[Icon] Disk Array #<Number>
Item
Description
<Number> Indicates the management number (logical address) of the Disk Array in the Universal RAID
Utility.
A Disk Array icon indicates the status of the Disk Array.
Icon
Meaning
Description
Disk Array - Normal All the created Logical Drives, all the member Physical Devices and all the
Dedicated Hot Spares operate normally. No failures have not been detected
by the RAID Controller.
Disk Array - Warning One or more Logical Drives, Physical Devices, or Dedicated Hot Spares are in
the warning condition in the Disk Array.
Disk Array - Fatal One or more Logical Drives, Physical Devices, or Dedicated Hot Spares are in
the warning or fatal condition in the Disk Array.
SSD Cache Disk Array
When you create SSD Cache Drive in the RAID Controller, you can see that SSD Cache Disk Array node for that
SSD Cache Drive is in the RAID Controller node. A single SSD Cache Disk Array node equals an SSD Cache Disk
Array, and shows the number of the SSD Cache Disk Array. The SSD Cache Drive you have created, all the
member Physical Devices exist in the SSD Cache Disk Array node.
[Icon] Disk Array #<Number> SSD Cache
Item
Description
<Number> Indicates the management number (logical address) of the SSD Cache Disk Array in the
Universal RAID Utility.