8.5 BMC Configuration
♦BMC Configuration tool
Among the BMC configuration information tools there are some tools which cannot be used to setup NEC ESMPRO
Manager.
NEC MWA Agent cannot be used.
If NEC MWA is stored in the EXPRESSBUILDER DVD-ROM, [A setup of a system management] stored in the
same EXPRESSBUILDER DVD-ROM cannot be used.
The Console-less function of the EXPRESSBUILDER can not be used when NEC MWA is stored in the same
EXPRESSBUILDER DVD-ROM.
♦In case of exchange of Management PC
If a Management PC as an alert receiver has been exchanged, register the managed server's BMC configuration
information again even when the IP address of the Management PC remains unchanged. Otherwise, the BMC may fail
to recognize the alert receiver.
♦Function "Obtain an IP Address automatically (DHCP)"
The managed server included the BMC that uses a Management LAN port supports the function "Obtain an IP Address
automatically (DHCP)".
1. Following version of NEC ESMPRO Manager modules supports the setting of the function.
Managed server DianaScope
DianaScope Manager Ver.1.07.01 or later
DianaScope PXE Service Ver.1.02.00 or later
DianaScope Agent Ver.2.03.05 or later
The managed server that integrates EXPRESSSCOPE
Engine series. DianaScope Manager Ver.1.07.01 or later
DianaScope Configuration Ver.1.02 or later
DianaScope Manager Ver.1.11.00 or later
DianaScope PXE Service Ver.1.03.00 or later *1
DianaScope Agent Ver.2.06.00 or later
The managed server installed Advanced Remote
Management Card or ft Remote Management Card.
DianaScope Configuration Ver.1.02 or later
*1 Not Support the managed server installed ft Remote Management Card.
When you use the module that does not support the setting of the function "Obtain an IP Address automatically
(DHCP)" for the managed server that supports the function, note followings :
- If DianaScope Agent does not support the setting of the function, the DianaScope Agent always set
[disable] for the function when it registers the BMC configuration. The DianaScope Agent also set [disable]
when it writes the BMC configuration information file.
- If DianaScope Configuration does not support the setting of the function, the DianaScope Configuration
always set [disable] for the function when it writes the BMC configuration information file.
- If [System Management] tool on EXPRESSBUILDER does not support the setting of the function, the tool
always set [disable] for the function when it registers the BMC configuration. The tool also set [disable]
when it writes the BMC configuration information file.