♦Power management
If you set the value on the managed server which does not support power management, you cannot put back the
value to "unsetting". Set "zero" to each value, it is accepted as "unsetting".
The electric power value might not necessarily reach even the value of Power Cap value.
The electric power control lowers the power consumption of the system by lowering the frequency of CPU /
Memory.
When CPU / Memory Throttling value reaches 100%, the electric power value doesn't fall any more.
For more detail about the Power Monitoring and Power Control Function, reference the following site.
http://www.58support.nec.co.jp/global/download/index.html
[Others] - [Technology paper]
♦CPU blade auto registration
When "Check Connection" of "CPU blade auto registration" was failed. You can execute "Check Connection" on
"Server Properties" - "Connection Setting".
If a specified IP address is set from a CPU blade to another CPU blade during "CPU blade auto registration" process
(ex. when you replace CPU blade and execute "CPU blade auto registration"), NEC ESMPRO Manager may not be
able to connect the CPU blade because old information remains in the ARP table on the management PC. Wait for a
few minutes and try the "Check Connection".
♦Coexistence of NEC ESMPRO Manager with DianaScope Agent or NEC ESMPRO
Agent Extension on the same server
If the managed server is installed Advanced Remote Management Card or EXPRESSSCOPE Engine series (the BMC
uses exclusive LAN port (management LAN port)), NEC ESMPRO Manager can manage the server itself installed. It
the managed server is installed BMC that uses the standard LAN port, NEC ESMPRO Manager cannot manage the
server itself installed. It is possible only to install NEC ESMPRO Manager and DianaScope Agent or NEC ESMPRO
Agent Extension on the same server. But the communication with BMC on the server is prevented by local loopback
function of OS and the BMC cannot receive any packets from the NEC ESMPRO Manager.
♦EM Card registration
When you resister the EM Card, you need to set valid on SNMP management and "Management Controller"
management each other.
If the connection is failed at "Auto Registration" or "Check Connection", it is not recognized as EM Card because
both management is invalid. In this case, set correct connection setting and execute "Check Connection" again.
If you register the EM Card from Operation Window, the EM Card is registered invalid status on NEC ESMPRO
Manager. So you need to execute "Check Connection" to manage it.