Installation Guide
1. In [Configuration] section, specify parameters.
In ˝Timeout ˝, specify number of seconds to stop collecting failure information.
In ˝MaxSize ˝, specify maximal size of collecting failure information log (count by KB).
When ˝0 ˝ is given, unlimitedly possible.
2. In [DefaultTools] section, specify log information for the case of not specifying individual log
commands.
In ˝Command ˝, specify the absolute path of log command.
In ˝Directory ˝, specify the absolute path where the log-gathering command is executed.
In ˝LogFile ˝, specify the absolute path.
When a folder is specified, the files under it (includes subfolders) are collected.
In ˝IPadr ˝, when IP address of the server in which failure occurred is passed to commands as parameters,
select [Yes].
When IP address is not passed, specify ˝NO ˝ or do not enter IPadr.
3. In [NoneTrouble] section, specify events that are not the targets for log-gathering.
Specify the events as ˝SourceNameXX ˝,˝EventIDXX ˝ (˝XX ˝ is any of the sequence number from ˝01 to 99 ˝).
In ˝SourceNameXX ˝ specify the source name of the target.
When ˝* ˝ is given, all source name are specified.
In ˝EventIDXX ˝, specify the target event ID.
Specify the event ID, all 32 bytes events, in hexadecimal beginning with ˝0x ˝.
Multiple event IDs can be given, separated by ˝, ˝. When ˝* ˝ is given, all event IDs are specified.
4. In [ToolYYY] section (YYY is any of the sequence number from ˝001 to 999˝), specify individual log
command.
In ˝Command ˝, specif
y the absolute path of log command.
In ˝Directory ˝, specify the absolute path where the log-gathering command is executed.
In ˝LogFile ˝, specify the absolute path.
When a folder is specified, the all files under it (includes subfolders) are collected.
Specify the events as ˝SourceNameXX ˝, ˝EventIDXX ˝ (˝XX˝ is any of the sequence number from ˝01 to 99 ˝).
In ˝SourceNameXX ˝, specify the source name of the target.
When ˝* ˝ is given, all source name are specified.
In ˝EventIDXX˝, specify the target event ID.
Specify the event ID, all 32 bytes events, in hexadecimal beginning with ˝0x ˝.
Multiple event IDs can be given, separated by ˝, ˝. When ˝* ˝ is given, all event IDs are specified.
In ˝IPadr ˝, when IP address of the server in which failure occurred is passed to commands as parameters,
select [Yes].
When IP address is not passed, specify ˝NO˝ or do not enter IPadr.
* Concerning the event that corresponds with multiple [ToolYYY], all collecting commands are executed.
In this case, Timeout is applied to the session until after all command execution is completed.
It is not applied to each collecting command.
* When no command is written in [DefaultTools] section, log-gathering is executed concerning only the event
defined in [ToolYYY].
* Even if ˝* ˝ is defined in [NoneTrouble] section, log collection of [ToolYYY] section log is executed concerning
the event written in [ToolYYY] section.
25