Maintenance Manual
1. POST Error Message
Express5800/R120d-1M, R120d-2M Maintenance Guide
114
Chapter 3 Appendix
BMC Message on Lower LCD Line Cause Solution
CPU2-DIMM10 Uncorrectable Error
An unrecoverable error occurred
for CPU2-DIMM10.
Contact your sales representative.
CPU2-DIMM11 Uncorrectable Error
An unrecoverable error occurred
for CPU2-DIMM11.
CPU2-DIMM12 Uncorrectable Error
An unrecoverable error occurred
for CPU2-DIMM12.
Processor1 Internal Error
An internal CPU error (IERR)
occurred.
Processor2 Internal Error
Sensor Failure Detected.
Abnormality in a sensor was
detected.
SMI timeout
A timeout occurred while
servicing system management
interrupts.
IPMI Watchdog timer timeout
(Power off)
A watchdog timer timeout
occurred.
Node Manager Firmware Image
execution Failed
Abnormality in Node Manager
occurred.
Turn off the power, wait for about 30
seconds, and restart the server. If this
does not resolve the problem, contact
your sales representative.
Node Manager Firmware Flash Erase
Error
Node Manager Firmware Flash
Corrupted
Node Manager Firmware Flash
Corrupted
Abnormality in Node Manager
occurred.
Turn off the power, wait for about 30
seconds, and
restart the server. If this
does not resolve the problem, contact
your sales representative.
Node Manager Internal Error
Node Manager can't communicate
BMC
Node Manager Firmware Image
execution Failed
Node Manager Firmware Flash Erase
Error
Node Manager Firmware Flash
Corrupted
Node Manager Internal Error
Node Manager can't communicate
BMC
Node Manager Manufacturing Error
Node Manager Persistent Storage
Integrity Error
Drive 0 Fault
Operation was performed during
hard disk drive failure
Turn off the power, wait for about 30
seconds, and restart the server. If this
does not resolve the problem, contact
your sales representative.
Drive 1 Fault
Drive 2 Fault
Drive 3 Fault
Drive 4 Fault
Drive 5 Fault
Drive 6 Fault