7.7 ECO setting
-- The electric power value might not necessarily reach even the value of Power Threshold. The electric
power control lowers the power consumption of the system by lowering the frequency of CPU/Memory.
When CPU/Memory Throttling value reaches 100%, the electric power value does not fall any more.
-- The server may not boot correctly if you configure too low value to the Aggressive Mode Power
Threshold(Pa) and enable the Shutdown System option.
-- The following case, ECO settings are not supported and not displayed.
"Operating System is Windows Server 2003(R2)." and "NEC ESMPRO Agent is installed."
7.8 Management LAN setting
-- When set to "Shared BMC LAN", the management LAN port is disabled.
-- When set to "Shared BMC LAN", the network performance may be reduced because the data of both
LANs must be transmitted or received.
7.9 Default setting
-- Please refer to the EXPRESSSCOPE Engine 3 User's Guide about differences between BMC
Configuration's default values and values which "BMC Configuration Initialization" function will set.