Removal
Remove a DIMM in the following procedure.
Note
When removing a defective DIMM, check error messages displayed at POST or
ESMPRO and check the DIMM socket where the defective DIMM is installed.
At least one DIMM needs to be installed for the server to operate.
1. Refer to steps 1 to 4 in Chapter 2 (1.3 Overview of Installation and Removal for preparations.
2. Lift the processor duct off the server.
3. Rotate both levers of the DIMM socket
outward. The socket is unlocked and
DIMM can be removed.
4. Refer to the procedure from steps 7 to
10 in Chapter 2 (1.3 Overview of
Installation and Removal) to put it back.
5. Turn on the server and confirm that no error messages are displayed on POST. If any error message
is displayed, refer to Chapter 3 (1. Post Error Message) in "Maintenance Guide".
6. Run the SETUP utility, select Memory Configuration from the Advanced menu, and then specify
Yes for Memory Retest. After that, select Save Changes and Exit to reboot.
7. Set the paging file size to the recommended value (Total memory size x 1.5) or more.
If using a Windows OS, refer to Chapter 1 (7.1 Specifying Memory Dump Settings (Debug
Information)) in "Installation Guide (Windows)".
For other OS, consult the manual provided with the operation system or contact the store where you
purchased it or your maintenance service company.