User Guide

BMC Configuration User's Guide
48
4.4.3 Battery Controller Configuration
This screen displays and sets the various functions of the battery controller.
Item Description Default Value
Battery Controller Configuration Battery Controller setting
Shutdown at power lost Select Enable/Disable of the ability to shutdown
at the power failure. *1
Disable
Shutdown delay time Set the timeout period until the shutdown will be
started at the power failure. *2 *3
0
Battery turn off delay time Set the timeout period until the shutdown will be
finished at the power failure. *2 *3
0
Boot after power recovery Select Enable/Disable of the ability to boot after
the power recovery. *2 *4
Disable
Boot timeout after DC-ON Set the timeout period until the boot is complete
after DC-ON. *2 *3 *5
0
*1: The POWER Switch should be configured to shutdown in the OS.
*2: It is possible to set only if Shutdown at power lost is set to "Enable".
*3: The battery output period may be briefer in duration than the each configured time in this item,
depending on the remaining charge.
*4: This item is valid only when AC-LINK is set 'Stay Off', or AC-LINK is set 'Last State' and Last State is
DC-OFF.
*5: This item is valid at DC-ON after the shutdown system by 'Shutdown at power lost'. (DC-ON by 'Boot
after power recovery' or manually)