Reference Guide

47
Type
Specify an alert type.
SNMP: SNMP alert
MAIL: MAIL alert
SensorName
Specify the key name of sensor. See the following list.
Level1
Specify the alert level of error.
Level2
Specify the alert level of warning.
Level3
Specify the alert level of information.
0: Disable to change SNMP alert or MAIL alert of alert level
1: Enable to change SNMP alert or MAIL alert to1 of alert level
2: Enable to change MAIL alert to2 of alert level
3: Enable to change MAIL alert to3 of alert level
4: Enable to change MAIL alert to1 or MAIL alert to2 of alert level
5: Enable to change MAIL alert to1 or MAIL alert to3 of alert level
6: Enable to change MAIL alert to2 or MAIL alert to3 of alert level
7: Enable to change MAIL alert to1,
MAIL alert to2 or MAIL alert to3 of alert level
8: SNMP alert and MAIL alert of unalterable alert level
TIP:
0 is specified for a unalterable alert level.
See the following list.
OK : Enable to change, NG : Disable to change
SensorName Contents Level1 Level2 Level3
TEMP_THRESHOLD Temperature
(Monitoring
Threshold)
OK OK OK
VOLT_THRESHOLD Voltage (Monitoring
Threshold)
OK OK OK
FAN_SENSOR FAN(Speed) OK OK OK
COOL_DEV_THRESHOLD Cooling Device
(Monitoring
Threshold)
OK OK OK
TEMP_ABNORMAL Temperature
(Monitoring Abnormal
State)
OK NG OK
POST_MEM_RESIZE POST Memory
Resize
NG OK OK
MODULE_BOARD Module/Board(Missin
g)
OK NG OK
SMI_TIMEOUT SMI Timeout OK NG OK
VOL_ABNORMAL Voltage (Monitoring
Abnormal State)
OK NG OK