User's Guide

9-78 Upgrading Your Server
16. Attach the removed components.
IMPORTANT:
If an N8151-81-internal MO (USB) or N8151-86-internal RDX (USB)
is connected, the boot order might be changed.
On the [Boot] menu of the BIOS setup utility, make the boot priority of
the above removable devices lower than the boot disk.
Procedure:
[Boot] [Boot Option #2] [(Bus 08 Dev 0 0) PCI RAID Adapter]
17. Install the device driver for the connected backup device.
For details, see the instruction manual that came with your backup device.
Removal
To remove a component, perform the steps for attaching it in reverse.
BACKUP FANS
By inserting optional fans into the expansion fan slots, you can ensure that the system is cooled
even if the main fans fail.
The following figure shows the standard fan slots, optional fan slots, and the slot numbers assigned
to each slot.
Front
Back
Optional
Standard
FAN 1F
FAN 1F
FAN 3F
FAN 4F
FAN 1R
FAN 2R
FAN 3R
FAN 4R