Reference Guide

49
See the following list for a fault tolerant server.
OK : Enable to change, NG : Disable to change
SensorName Contents Level1 Level2 Level3
TEMP_THRESHOLD Temperature
(Monitoring
Threshold)
NG OK OK
VOLT_THRESHOLD Voltage (Monitoring
Threshold)
NG OK OK
FAN_SENSOR FAN(Speed) NG OK OK
PROCESSOR Processor NG OK OK
PW_SUPPLY Power Supply NG OK OK
PW_UNIT_STS Power Unit State NG NG OK
MEM Memory NG OK OK
POST_ERR POST NG OK OK
EVT_LOG_DISABLED Event Logging NG NG OK
SYS_EVT System Event NG NG OK
CRITICAL_INT Critical Interrupt OK NG OK
BUTTON_SWITCH Button/Switch NG NG OK
SYS_BOOT_RESTART_INIT System Boot/Restart
Initiated
NG NG OK
BOOT_ERR Boot Error NG NG OK
SLOT_CONNECTOR Slot/Connector NG NG OK
ACPI System ACPI Power
State
NG NG OK
WATCHDOG_TIMER Watchdog Timer NG OK OK
SENSOR_FAILURE Sensor Failure NG OK OK
HA EVENT HA Event OK OK OK
See the following list for the server which has EXPRESSSCOPE Engine SP3 (2BMC model).
OK : Enable to change, NG : Disable to change
SensorName Contents Level1 Level2 Level3
TEMP_THRESHOLD Temperature( Monitori
ng Threshold)
OK OK OK
VOLT_THRESHOLD Voltage(Monitoring
Threshold)
OK OK OK
FAN_SENSOR FAN(Speed) OK OK OK
POST_MEM_RESIZE POST Memory
Resize
NG OK OK
SMI_TIMEOUT SMI Timeout OK OK OK
VOL_ABNORMAL Voltage (Monitoring
Abnormal State)
OK OK OK
PROCESSOR_ABNORMAL Processor(Monitoring
Abnormal State)
OK OK OK
MODULE_BOARD_ABNORMAL Module/Board(Monitor
ing Abnormal State)
OK NG OK
MODULE_BOARD_DISABLED Module/Board(Monitor
ing Disabled State)
NG NG OK
SLOT_CONNECTOR_DISABLED Slot/Connector(Monit
oring Disabled State)
OK OK OK