Reference Guide
46
2.2.25 setAuthKey
Syntax:
dscli setAuthKey Component OldPassword NewPassword SelectAuthKey
Description:
Changes the authentication key, PPP server’s password or SMTP server’s password of a BMC configuration.
The parameter supported according to the kind of BMC is different.
TIP:
After you succeed to change authentication key, you should change the authentication key
registered on NEC ESMPRO Manager using setComponentProperty command. See 2.2.9
setServerProperty.
Options:
Component
Specify the name, the MAC address of LAN port that BMC uses, or the GUID of the managed
component.
OldPassword
Specify current password.
NewPassword
Specify new authentication key or PPP sever’s password up to 16 characters.
Specify new SMTP server’s password up to 20 characters.
SelectAuthKey
Specify a type of password.
0 Authentication key
1 Password of primary PPP server
2 Password of secondary PPP server
3 Password of SMTP server
2.2.26 setSensorLevel
Syntax:
dscli setSensorLevel Component Type SensorName Level1 Level2 Level3
Description:
Changes separate setting at the alert level of BMC configuration information on the managed component.
This command can be used when alert Level is only a separate setting.
TIP:
Use setBmcInfo command to change alert level to the separate setting of component. See
2.2.23setBmcInfo.
8 is not use. Use getSensorLevel command. See 2.2.27 getSensorLevel.
Options:
Component
Specify the name, the MAC address of LAN port that BMC uses, or the GUID of the managed
component.