Reference Guide

63
/x ModuleNo
Specify the CPU/IO module number (0 or 1) if the managed component is a fault tolerant server.
If you omit this parameter for the fault tolerant server, this command obtains the status of the CPU/IO
module 0.
Output:
Displays the status of the sensor. The following shows an example.
Current Value:
30.00 degrees C
Current Status:
Normal
Upper non-recoverable Threshold:
---
Upper critical Threshold:
46.00 degrees C (Hysteresis:44.00 degrees C)
Upper non-critical Threshold:
43.00 degrees C (Hysteresis:41.00 degrees C)
Lower non-critical Threshold:
3.00 degrees C (Hysteresis:5.00 degrees C)
Lower critical Threshold:
0.00 degrees C (Hysteresis:2.00 degrees C)
Lower non-recoverable Threshold:
---
2.2.46 getConsoleLog
Syntax:
dscli getConsoleLog Component
Description:
Displays the console log of a specified component.
Options:
Component
Specify the name, the MAC address of LAN port that BMC uses, or the GUID of the managed
component.
Output:
Displays the console log of a specified component.