Setup Guide
NEC ESMPRO Manager Ver.5 Setup Guide
84
CHECK:
Place the configuration information FD in the write-enable state
3.2.2.2 Run NEC EXPRESSBUILDER DOS based with remote console feature
(1) Configure the BMC of the managed component with the configuration information.
Insert the NEC EXPRESSBUILDER CD-ROM into the CD-ROM drive and the “configuration information
FD” into the FD drive on the managed component. And then turn on the component.
After NEC EXPRESSBUILDER DOS based with remote console feature is started and the
configuration information is loaded from the FD into the managed component, the Operating System
will be rebooted.
TIPS:
If the setting in the configuration information file is already configured, the managed
component will be not rebooted.
When the console-less function for direct connection is used, the BIOS settings are
changed as follows:
Serial Port Address: On Board COM B
Baud Rate: 19.2kbps
Flow Control: RTS/CTS for the managed server supporting SOL
No Flow for the managed server not supporting SOL
Terminal Type (Console Type) : PC-ANSI
To check whether that the managed server supports SOL, see ” Appendix C. Managed
Components Summary”
The managed component is still opened the main menu of the NEC EXPRESSBUILDER
after executing the feature.
After registering the managed component on the NEC ESMPRO Manager and confirm the
remote console for the managed component, remove the NEC EXPRESSBUILDER from
the CD-ROM drive if you need.