product does not support it.
2-(m) The power measurement for the server 1 reads a total of the server 1 and the server 2. The
power measurement for the server 2 always reads 0.
2-(n) Please execute “check connection” for the managed component when BMC FW is updated
on the managed component. If “check connection” is not executed, the remote console
function may not run normally.
2-(o) If the managed component is Dual Server System, the power measurement for each server reads a total
of the server 1 and the server 2.
2-(o) Power supply state display is partly different from module POWER lamp on the device. Only DC
on(turn on green lamp) and DC off(turn off green lamp) correspond in ESMPRO/ComponentManager.
3. About the operation
3-(a) Only one NEC ESMPRO Manager can control this product.
3-(b) Serial Console Redirection and LAN Console Redirection cannot be used concurrently. To use LAN
Console Redirection, disconnect the cable from the serial port 2 on the front panel, or set the
configuration item “Redirection (WAN/Direct)" to "Disabled”.
3-(c) If Linux has been installed in this product, be sure to set the BMC configuration item “Redirection
(WAN/Direct)” to “Disabled”. If it is enabled, Linux cannot be booted.
3-(d) To use the remote console function on this product, select “Advance” – “Memory Configuration” and
set “Extended Memory Test” to “Disabled” on the BIOS Setup Utility screen.
3-(e) Following function cannot be used for this product in implementation:
- CUI Remote console function
- Remote drive function
- Power control function
- Scheduled running function
3-(f) Please do not change the delay time on the Power Restore Delay function for this product. This
product is turned on after the waiting time ((slot number - 1) * 2sec). If the delay time is changed from
0 sec (the default value), the waiting time is not set correct value.
EM Card List
NEC ESMPRO Manager can get a blade enclosure information by communication with the following EM
Card in the blade enclosure.
--EM Card [N8405-019A]
--EM Card [N8405-27]
--EM Card [N8405-043]
Power Bay
NEC ESMPRO Manager can manage the following Power Bay remotely.
--EcoPowerGateway [N8142-36F]