User's Guide

4. Names and Functions of Parts
Chapter 1 General Description
4.7.7
LED on a Hard Disk Drive
The DISK LED on a Hard Disk Drive to be installed in the Hard Disk Drive bay indicates different states.
DISK LED
3.5-inch Hard Disk Drive
DISK LED
2.5-inch Hard Disk Drive
The LED flashes green
This indicates a Hard Disk Drive is being accessed.
The LED flashes amber
When Logical Drives are configured in the RAID System, this indicates the instal
led Hard Disk Drive is
broken.
When Logical Drives (RAID 1, 5, 6, 10, and 50) are configured in the RAID System, the
Tips
system can continue to operate even if one Hard Disk Drive (2 drives in the case of RAID 6)
failed. However, we recommend you replace the failed Hard Disk Drive and perform
rebuilding as soon as possible (Hard Disk Drives are replaced by using hot swapping).
The LED flashes green and amber alternately
Th
is indicates that a Hard Disk Drive is being rebuilt (not a defect). In a RAID S
ystem, the Hard Disk
Drive is automatically rebuilt upon replacing a broken Hard Disk Drive (auto build function). The LED
flashes green and amber alternately while a Hard Disk Drive is being rebuilt.
The LED goes off when rebuilding completes. If rebuilding fails, the LED flashes amber.
Important Observe the following precautions whenever you use the auto build function.
Do not turn off or reboot the server while a Hard Disk Drive is being rebuilt.
Wait at least 90 seconds before installing a Hard Disk Drive after removing one.
Do not replace a Hard Disk Drive while another Hard Disk Drive is being rebuilt.
Express5800/R110d-1E, E110d-1 User’s Guide
43