User's Guide

BMC Configuration User's Guide
28
Item Description Default Value
Safe Power Capping Safe Power Capping setting
Safe Power
Capping(Power Reading
Timeout)
Select Enable/Disable of the watch operation when the
power value can not be read from the power supply.
Disable
ECO Info. The reference value and the statistics value of the
managed server are displayed.
*1: In order to perform continuous operation of the managed server, the function controls the total power
consumption so as not to exceed the specified value. It is effective when you want to make full use of limited
electric power and when you don't want to consume excessive electric power.
*2: It is possible to set when CPC is "Enable".
*3: XXX is Minimum Configuration of Idle or "Power Cap value(Pn)".
*4: When the power exceeds "Power Cap value(Pc)" for more than the seconds of this value, the alert or
shutdown is executed.
*5: It is possible to set when NCPC is "Enable".
*6: YYY is Maximum Configuration of During Operation or "Power Cap value(Pc)".
*7: When the power exceeds "Power Cap value(Pn)" for more than the seconds of this value, the alert is
executed.
IMPORTANT:
The ECO screen is not displayed if the managed server does not support this function.