User's Guide
2. System BIOS Setup
Express5800/GT110e-S User’s Guide
128
Chapter 3 Setup
2.4
Cases that Require Configuration
Only if a case applies to any of following cases, use the SETUP utility to change a parameter which was
configured as factory setting. Other than cases described below, do not change the settings. A list of SETUP
parameters and factory settings are described in Chapter 2 (1. Details of System BIOS) in "Maintenance
Guide".
Category Description To be changed Remark
Basic Change date and time
Main → System Date
Main → System Time
Configurable on OS
On/Off NumLock on power ON
Boot → Bootup Numlock State
On/Off the function to display
the NEC logo during POST
Boot → Quite Boot → Disabled
By pressing the <Esc> key,
prevent the display of the logo.
Optional
board
Install RAID Controller board
Advanced → PCI Configuration → PCI
Slot n Option ROM → Enabled
n is PCI slot number of the
RAID Controller
Boot Change the boot order of
devices
Boot → Boot Option Priorities →
Change the boot priority
Use remote power on function
(from modem)
Advanced → Advanced Chipset
Configuration → Wake On Ring →
Enabled
Use remote power on function
(from RTC alarm)
Advanced → Advanced Chipset
Configuration → Wake On RTC Alarm
→ Enabled
Control from HW console
terminal
Advanced → Serial Port Configuration
→ Change respective setting.
Security Set a password
Security → Administrator Password
→ Enter a password
(Set a password for Administrator first
and then User)
There are two types of
password; Administrator and
User.
Settings for User password is
limited compared to for
Administrator.
UPS
Powerlink
When the server is supplied
with power from UPS, always
turn on the power.
Server → AC-LINK → Power On
If it is turned off by using
POWER switch, leave it OFF
even when UPS supplies
power.
Server → AC-LINK → Last State
Keep the power OFF even
when UPS supplies power.
Server → AC-LINK → Remains off