Maintenance Manual

4. RAID System Configuration
Express5800/GT110e-S Maintenance Guide
84
Chapter 2 Convenient Features
4.2
Menu Tree
: Selection and execution parameter : Setting parameter : Data display
: Can be set or modified after a virtual drive is created
(1/2)
Menu Description
Configure Specify configuration settings
Easy Configuration Set a configuration using fixed values
New Configuration Set a new configuration
View/Add Configuration Add or view a configuration
Clear Configuration Clear the configuration data
Select Boot Drive Select a virtual drive to be booted
Initialize Initialize the virtual drive
Objects Set up various objects
Adapter Set up the RAID Controller
Sel. Adapter Select an adapter
Rebuild Rate 30
Chk Const Rate 30
FGI Rate 30
BGI Rate 30
Disk WC Off
Read Ahead On
Bios State Enable
Cont on Error Yes
Fast Init Enable
Auto Rebuild On
Auto Resume Enable
Disk Coercion 1 GB
Factory Default Reset to the default values
Virtual Drive Operate a virtual drive
Virtual Drives Select a virtual drive (when multiple virtual drives exist)
Initialize Initialize the virtual drive
Check Consistency Check virtual drive consistency
View/Update Parameters View the virtual drive information
RAID View the RAID level
SIZE View the virtual drive capacity
Stripe SIZE View the stripe size
#Stripes View the number of Hard Disk Drives in the virtual drive
State View the virtual drive status
Spans View the span setting
Disk WC View the write cache setting
Read Ahead View the read ahead setting