Maintenance Manual
5. Troubleshooting
Express5800/GT110e-S Maintenance Guide
34
Chapter 1 Maintenance
[?] Event ID508: If the N8103-141 or N8103-153 extra battery is mounted, the following message is registered
in the RAID log of Universal RAID Utility and OS logs (Windows event log, Linux syslog)
Event source : raidsrv
Event ID : 508 (800001FC)
Type : Warning
Description : <RU0508> [CTRL: Number of RAID Controller] The battery status is
unstable.
Did the battery become unstable immediately after the extra battery had been mounted?
→ Immediately after the extra battery is mounted, this event may be registered till the battery refresh
operation is completed.
If this message is registered, wait for about 15 minutes and check the Cache Mode (current value) of the
RAID Controller. If the Cache Mode (current value) is Write Back, use the battery as is because there is no
problem.
→ If the current cache mode is set to “Write Through”, the battery needs to be refreshed. Contact your
service representative.
If “Write Through” is retained for 9 hours or more after starting refresh operation, the battery may be
faulty. Replace the battery.
[?] Event ID510: The following event is logged in RAID log of Universal RAID Utility and OS log (Windows
event log or Linux syslog) when additionally battery is installed.
Event source : raidsrv
Event ID : 510
Type : Info
Description : <RU0510> [CTRL: Number of RAID Controller]
Battery Refresh required.
→ Use Universal RAID Utility to perform battery refresh manually. Refer to Universal RAID Utility User's
Guide stored in EXPRESSBUILDER for more information.
[?] DISK LED flashes
DISK LED flashes frequently even while the Hard Disk Drive is not accessed.
→ When Patrol Read is running, the DISK LED flashes even if the Hard Disk Drive is not being accessed. If
SATA Hard Disk Drive is used, the DISK LED may stay on.