Maintenance Manual

1. POST Error Message
Express5800/GT110e-S Maintenance Guide
117
Chapter 3 Appendix
(3/3)
Error Message Description Recommended Action
C10E
BMC SDR Repository empty.
BMC device (chip) error Turn off the power, wait for about 30
seconds, and restart the server. If this
does not resolve the problem, contact
your service representative.
C10F
IPMB signal lines do not
respond.
SMC (Satellite Management
Controller) failure
C110
BMC FRU device failure.
Failure of the SROM for storing
chassis information
C111
BMC SDR Repository
failure.
Failure of the SROM for storing
sensor data record information
C112
BMC SEL device failure.
BMC device (chip) failure
C113
BMC RAM test error.
BMC RAM error
C114
BMC Fatal hardware error.
BMC error
C11B
BMC Mezzanine card is not
found.
BMC Mezzanine card is not
mounted.
Contact your service representative.
C11C
BMC Mezzanine partition
is invalid.
BMC Mezzanine partition is
invalid.
C200
The error occurred during
memory configuration
check.
The memory information could
not be obtained.
Turn off the power and restart the
server. If this does not resolve the
problem, contact your service
representative.
C201
Memory Configuration
change is detected.
The memory configuration has
changed since the previous
startup.
When Check previous system
Config is enabled in server of the
setup, this message appears if the
configuration was changed since the
previous startup. If this message
appears even when no configuration
change has been made, contact your
service representative.
C202
The error occurred during
CPU configuration check.
The CPU information could not
be obtained.
Turn off the power and restart the
server. If this does not resolve the
problem, contact your service
representative.
C203
CPU Configuration change
is detected.
The CPU configuration has
changed since the previous
startup.
When Check previous system
Config is enabled in server of the
setup, this message appears if the
configuration was changed since the
previous startup. If this message
appears even when no configuration
change has been made, contact your
service representative
C300
Out-of-band setup
configuration failure
Invalid access to BMC
Mezzanine card
Contact your service representative.
C301 SDR mismatch error
Inconsistency in the hardware
information of the sensor data
record was detected
Contact your service representative.