Maintenance Manual
1. POST Error Message
Express5800/GT110e-S Maintenance Guide
116
Chapter 3 Appendix
(2/3)
Error Message
Description
Recommended Action
C000
The error occurred during
fan sensor reading.
An error occurred during fan
sensor reading.
Contact your service representative.
C001 Fan 1 Alarm occurred.
An abnormality occurred in Fan
1.
It is possible that a fan has failed or is
clogged Contact your service
representative and request repairs.
C002 Fan 2 Alarm occurred.
An abnormality occurred in Fan
2.
C003
Fan 3 Alarm occurred.
An abnormality occurred in Fan
3.
C004
Fan 4 Alarm occurred.
An abnormality occurred in Fan
4.
C005 Fan 5 Alarm occurred.
An abnormality occurred in Fan
5.
C010
The error occurred during
temperature sensor
reading
An error occurred while reading
the temperature sensor.
Contact your service representative.
C011
System Temperature out of
the range.
A temperature abnormality was
detected.
It is possible that a fan has failed or is
clogged. Contact your service
representative and request repairs.
C020
The error occurred during
voltage sensor reading.
An error occurred while reading
the voltage sensor.
Contact your service representative.
C021
System Voltage out of the
range.
A system voltage abnormality
was detected.
C040
SROM data read error
SROM data reading error
C061
1st SMBus device Error
detected.
An error occurred in the 1st SM
Bus.
C062
2nd SMBus device Error
detected.
An error occurred in the 2nd SM
Bus.
C063
3rd SMBus device Error
detected.
An error occurred in the 3rd SM
Bus.
C064
4th SMBus device Error
detected.
An error occurred in the 4th SM
Bus.
C065
5th SMBus device Error
detected.
An error occurred in the 5th SM
Bus.
C066
6th SMBus device Error
detected.
An error occurred in for the 6th
SM Bus.
C067
7th SMBus device Error
detected.
An error occurred in the 7th SM
Bus.
C068
8th SMBus device Error
detected.
An error occurred in the 8th SM
Bus.
C103
BMC core hardware
failure.
BMC device (chip) error
Turn off the power, wait for about 30
seconds, and restart the server. If this
does not resolve the problem, contact
your service representative.
C104
BMC IBF or OBF check
failed.
Accessing the BMC address
failed.
C105
BMC SEL area full.
There is not enough capacity to
write the system event log.
Start up the offline tools and delete
the event logs.
C10C
BMC update firmware
corrupted.
BMC device (chip) error
Turn off the power, wait for about 30
seconds, and restart the server. If this
does not resolve the problem, contact
your service representative.
C10D
Internal Use Area of BMC
FRU corrupted.
Failure of the SROM for storing
chassis information