Installation Guide
Table Of Contents
- Cover
- Documents Provided with This Product
- Contents
- Notations Used in This Document
- Trademarks
- Regulatory Notices
- Warnings and Additions to This Document
- Chapter 1 Installing Windows
- 1. Before Starting Setup
- 2. Setting Up the Operating System
- 3. Setting Up Windows Server 2008 R2
- 4. Setting Up Windows Server 2008
- 4.1 Before Starting Setup
- 4.2 Setup with EXPRESSBUILDER
- 4.3 Setup with OS Standard Installer
- 4.4 Installing Starter Pack
- 4.5 Setting Up Device Drivers
- 4.6 Specifying PAE Option
- 4.7 Installing the Bundled Software
- 4.8 License Authentication
- 4.9 Applying Service Pack
- 4.10 Installation When Multiple Logical Drives Exist
- 5. Setting Up Windows Server 2003 R2 x64 Edition
- 6. Setting Up Windows Server 2003
- 7. Setup for Solving Problems
- 8. Windows OS Parameter File
- Chapter 2 Installing the Bundled Software

5. Setting Up Windows Server 2003 R2 x64 Edition
Express5800/GT-110e, GT-110e-S, R110e-1E Installation Guide (Windows)
189
Chapter 1 Installing Windows
9. You can use the default setting for Probe interval and Probe maximum retries. If you change these
values, select a value from each drop-down list, click the target probe (Probe Target xx), and then click
[Edit Target IP Address…].
Tips
• The setting range of Probe interval (link packet transmission interval) is 1 to 60
(units: seconds).
• The setting range of Probe maximum retries (link packet retry count) is 1 to 10
(times).
• Switching a path upon detection of a communication path error by LiveLink takes
(Probe maximum retries + 1) x Probe interval (seconds) at maximum.
If a link is down is detected, failover occurs immediately after the link goes down.
It takes the time specified for Probe interval (seconds) to recover from the link
going down.
10. In the Target xx text box, enter the IP address of the alive monitoring server, and then click [OK].
Important
• Target xx must be the same broadcast domain as that specified for the data
communication IP and LiveLink communication IP (described in step 13).
Specify an IP address that exists on the network and with which
communication is possible.
• If communication with the IP address specified in Target xx is not possible,
the team will also be unable to communicate. It is therefore recommended
that you specify multiple IP addresses using Probe Target. Up to four IP
addresses can be specified.