User's Guide
Troubleshooting 8-7
Error
code
Error message Recommended Action
0615 Com B configuration changed
0616
Com B config. error - device
disabled
Check if COM B is properly configured.
0B00
WDT timeout occurred at previous
boot in POST.
0B01
WDT timeout occurred at previous
boot in OS boot.
0B02
WDT timeout occurred at previous
boot in OS running.
Reboot (reset) the server. If the server starts
normally, confirm the DMI log.
0B28
Unsupported CPU detect on CPU
Slot
Contact your service representative.
0B60 DIMM group #1 has been disabled
0B61 DIMM group #2 has been disabled
0B62 DIMM group #3 has been disabled
0B63 DIMM group #4 has been disabled
0B6F DIMM group with error is enabled
Contact your service representative.
0B7E
Mismatched FAN control Mode
setting. Please set the FAN control
mode on BIOS SETUP.
Run BIOS SETUP and provide setting again.
0BB0 SMBIOS - SROM data read error.
0BB1 SMBIOS - data checksum bad.
Contact your service representative.
8151 Password Cleared By Jumper
Power off the server, then change the password clear
jumper switch to its original position.
8800 PECI - Communication Error Contact your service representative.
9000
PCI Slot#1 PCIE Link Training
Error.
9001
PCI Slot#2 PCIE Link Training
Error.
9002
PCI Slot#3 PCIE Link Training
Error.
Remove the PCI card from the slot that shows an
error, then install the PCI card again. If the same
error persists, contact your service representative.
-
Expansion ROM not initialized - PCI
Mass Storage Controller in slot xx
If the hard disk drive connected to RAID Controller or
LAN board (for network boot) does not contain any
OS, disable Option ROM Scan for that PCI slot.