Technical Reference Guide
ftSMC Component Properties
3-4 Express5800/320Ma: Technical Reference Guide
Current Count The current MTBF value for a device. A 0 or Unknown value means
that the device has not failed often enough to calculate MTBF data.
CurrentReading Specifies the current value of a sensor. Depending on the sensor,
values are in degrees Celsius (
o
C) for temperature sensors,
millivolts (mV) for voltage sensors, revolutions per minute (rpm) for
fan speed sensors, or milliamperes (mA) for current sensors.
Customer Contact Name Contact person in your company who is responsible for the system.
Customer Email Email address of your company contact.
Customer Pager Pager number of your company contact.
Customer Phone Telephone number of your company contact.
DebugFlags:Irql
DebugFlags:Thread
When these flags are enabled, debug trace messages printed using
these flags will be logged.
DefaultGateway For systems equipped with VTMs. The IP address of the default
gateway used for traffic that goes to a network for which the adapter
has no route (for example, to NEC Technical Support or other
service representative, in communication from the system to the
adapter).
Defer Bringup Defers the automatic return-to-service of the CPU element (CPU
bringup) to a more convenient time.
Description A description property that helps you identify a particular ASN
configuration.
DeviceID An address or other identifying value that uniquely names a logical
device.
DevicePath[n] A string of slash-separated DeviceIDs that shows the relationship of
a device within a hierarchical ordering of devices. The DevicePath
property shows what other devices a particular device is connected
to, or is a child of.
DevicePathID Device identifier used to physically locate hardware components
within a system. A DevicePathID is a string of decimal numbers
such as 10/5/0/2.
For a virtual disk, the DevicePathID does not indicate a hardware
component, but instead identifies the virtual disk to system
management software.
DiagScreen Specifies whether the BIOS Diagnostics screen should be displayed
during the boot process.
Table 3-1. ftSMC System Inventory Component Properties (Continued)
Property Description