Express5800/320Lb System Release Notes 5
When backup software is installed and a PCI module needs to be serviced,
terminate the backup software service before replacing PCI modules.
Precautions
The following are precautions and limitations of the ft control software Version 3.0 for the
Express5800/320Lc/Lc-R. Please read the list of notices below carefully to ensure that they are
followed.
1. Precautions for relocating the Server
When relocating the server after setup, there is a possibility that some connectors
which connect the back panel and each module becomes broken due to shock or
vibration caused by transportation or inappropriate packing. This could cause a fatal
problem to the server. Please read the following, if you need/plan to relocate the server
after setup:
a) If you perform pre-setup to the server at a temporary place, keep the packaging box
and reuse it when relocating the server.
b) When relocating or transporting, remove all module from the main chassis and
pack each module. This does not mean that you need to prepare boxes for each
module. One box may contain one or more modules. If you plan to relocate the
server later, it is recommended that you keep the packaging box and reuse it when
relocating the server.
c) If you relocate a 320Lc-R (rack-mount model), remove all modules from the main
chassis before moving the main chassis. Even when relocating the server without
packing (e.g. by a hand cart), remove all modules from the main chassis before
moving the main chassis.
2. Precautions when adding HDD
When an unused HDD (no signature) is added, in rare instances, the redundancy of the
PCI modules will become failed. (Status LED2 of the PCI module in which the HDD
was added, will be lit amber.)
When status LED2 of the PCI module in which the HDD was added is lit amber, the
problem can be rectified using [Disk Management] from [Computer Management] (My
Computer Properties). Initialize the newly added HDD, by right clicking the HDD,
and click [Initialize Disk]. After the initialization, duplication of the PCI modules
should commence, and the status LED2 of the PCI module will become green.