User's Guide
C-2
System Status Hardware Support Information
System Status Hardware Support Information
This appendix helps you identify and find a system status hardware item indicated by a
software monitoring component.
The software monitoring component as it is related to the hardware system status item
is listed in the following table:
Software Monitoring Component/Hardware System Status Item
Software Monitoring Component Hardware System Status Item
ESMPRO Server Management View status based on polling the machine
Not all items can be monitored with every software component. Monitoring capability
relates to how the software component interacts with system hardware. ESMPRO
interacts with all hardware components. In this system, the SCSI Accessed Fault-
Tolerant Enclosure (SAF-TE) interface board is connected to the SCSI backplane. (See
Figure "System Chassis (Right Side View)" under "System Overview" in Chapter 1 of
this guide.)
The "Monitor Matrix" table below shows a component relating to selected status item.
This table also relates the terminology used by the software component to the system
hardware.
Monitor Matrix
Item ESM PRO Item Location Board Marking
Chassis front fan As Item Baseboard Fan3
Chassis upper rear fan As Item Baseboard Fan1
Chassis lower rear fan As Item Baseboard Fan2
Internal disk fan – upper Internal upper disk (SAF-TE) SCSI-BP J2
Internal disk fan – middle Middle SCSI-BP J1
Internal disk fan – lower Lower SCSI-BP J3
Intrusion switch - front Chassis cover SCSI-BP J6
Interlock switch - left side (front view) N/A SCSI-BP J5 pins 1, 2
Interlock switch - right side (front view) N/A SCSI-BP J5 pins 3, 4
(1)Power Supply fan (1) Power (SAF-TE) P. S. (Bottom) N/A
(2)Power Supply fan (2) Power (SAF-TE) P.S. (Top) N/A
SCSI-BP = SCSI Backplane