User's Guide
5-16
Problem Solving
Post Error Codes and messages (Continued)
Code Error Message
0B80 BMC Memory Test Failed
0B81 BMC Firmware Code Area CRC check failed
0B82 BMC core hardware failure
0B83 BMC IBF or OBF check failed
0B90 BMC Platform Information Area Corrupted
0B91 BMC update firmware corrupted
0B92 Internal Use Area of BMC FRU corrupted
0B93 BMC SDR Repository empty
0B94 IPMB signal lines do not respond
0B95 BMC FRU device failure
0B96 BMC SDR Repository failure
0B97 BMC SEL device failure
0BB0 SMBIOS - SROM data read error
0BB1 SMBIOS - SROM data checksum bad
0BD0 1
st
SMBus device address not acknowledged
0BD1 1
st
SMBus device Error detected
0BD2 1
st
SMBus timeout
0C00 RomPilot reports error number xx
None Expansion ROM not initialized
None Invalid System Configuration Data
None System Configuration Data Read error
None Resource Conflict
None System Configuration Data Write Source
None NOTICE: Your System Redundant Power Supply is not configured
None WARNING:IRQ not configured